READING PRESENT FAILURES
When the “Failure” function is displayed, press the confirm
button “ ” to display the current failures.
If no failures are currently present, after pressing the
confirm button “ ” the message “End failures” will be
displayed.
TECH>
SET PARAMETERS
TECH>
CASH
RESET
By confirming this function all current failures will be reset.
Coin mechanisms
It is possible to decide which of the payment system
protocols available are to be enabled for the functions.
The available payment systems are:
- Validators
- MDB
By selecting one of the systems it is possible to control its
functions.
Validators
When the “Validator Lines” function (line programming) of
the “programming” menu is displayed, the value of the 6
Validator coin lines, A to F, can be changed.
MDB
The MDB protocol menus are used for defining the follow-
ing functions:
Type of vending
Change control
Maximum credit
Maximum change
Accepted coins
Returned coins
Accepted bills
Minimum level of tubes
Accepted coins with “exact amount”
TECH>
FAILURES
FAILURE LIST
End of failures
TECH>
FAILURES
TECH>
RESET FAILURES
PROGRAMMING PARAMETERS
CASH
This set of functions controls all parameters regarding the
payment systems and the sales prices.
Selection prices
Four different prices can be set for each selection accord-
ing to the programmed time bands for when the time table
option is enabled.
For each of the 4 time bands prices (0 to 65,535) can be
programmed globally (same price for all selections) or for
the single selections.
Should the majority of products be sold at the same price,
it will be convenient to set the price globally and then
change the figure of the selections with different prices.
Time bands
Four programmable time bands are provided for selling
products at different prices.
The time periods are programmable for beginning and end
time by hours (00 to 23) and minutes (00 to 59).
If the values for start and end of the time band are set to
00.00 the time period is disabled.
The reference time is kept by an internal clock, program-
mable as:
day/month/year week-day 1-7
and then
hour/minutes/seconds.
If the values for start and end of the time band are set to
00.00 the time period is disabled.
Summary of Contents for Korinto UL 120V
Page 2: ......
Page 4: ......
Page 13: ...9 by N W GLOBAL VENDING SpA 07 06 275 00 The disassembly sequence is indicated below Fig 12...
Page 95: ...by N W GLOBAL VENDING SpA NOTE...
Page 96: ...N W GLOBAL VENDING S P A Sx44201...
Page 97: ...Koro FB 120V UL...
Page 98: ...by N W GLOBAL VENDING SpA NOTE...
Page 100: ......