Page 5-30
NDA-24230 Issue 2.0
Chapter 5
VisuaLink 128/384 User Guide
➂
Press the CALL PAGE button to advance to the Initialize screen.
Note:
Clear custom register options are: All, Speed dial, Redial, and Camera
Preset.
➃
Using the CAMERA CONTROL button highlight the appropriate
initialization and press the ENTER button.
Note: Environment setting initialization allows the user to select preconfigured
settings.
Note: Custom setting initializes the entire VisuaLink. When you power the
VisuaLink OFF and back ON, the start up configuration menu will appear.
Environment setting initialization
Clear custom register: <Speed dial>
Previous page: CALL PAGE
Press ENTER after choosing.
▲
Applications
1. Rollabout/Other
2. Data Conference
3. Gateway
4. Desktop
Input application number.
Press CANCEL to page back.
SETTINGS
ROLLABOUT/
OTHERS
DESKTOP
DATA
CONFERENCE
GATEWAY
Serial 1
Camera
Camera
T120
Camera
Serial 2
Console
Console
Console
Console
MLP
4.0
4.0
24.0
4.0
LSD
1.2
1.2
OFF
1.2
Audio Mode
G.722
G.722
G.728
G.722
Ent. Remote
Controller
Auto
OFF
OFF
OFF
H.263
OFF
OFF
OFF
OFF
Motion/Resolution
Motion
Motion
Motion
Motion
LIP Sync
ON
ON
ON
ON
Answer Mode
Auto
Manual
Manual
Auto
Summary of Contents for VisuaLink 128/384