CHAPTER 2 SYSTEM CONFIGURATION
UNIVERGE NEAX 2000 IPS General Description
Page 47
Issue 5
•
Set the unique trunk route to each Site.
•
Different numbering plan for every site must not be assigned.
•
Since Main Site controls OAI, OAI terminals cannot be used at Remote Site during
survival mode operation.
•
Each Remote Site must provide a hold tone to the station at the Remote Site.
-
External hold tone (using Jack on the MP card): Tone source is required for each
site.
-
Internal hold tone: Available
-
Hold tone using DAT: Not available
•
The maximum station number which can be used in SMDR or PMS Interface is as
follows.
-
MP built-in SMDR/PMS on IP: 1020 stations
-
SMDR/PMS with AP00 on RS-232C: 504 stations
•
You can connect MAT to Remote Site via RS-232C or LAN.
•
SNMP is not available at Remote Site.
•
The IP Remote Site does not have DHCP server and client function.
•
The MJ/MN alarm indications are not available at Remote Site. If a fault occurs at
Remote Site, the fault is notified to the Main Site and MJ/MN alarm is indicated at
the Main Site.