OPERATION
ROI-S04488
3-10
SEL V (LINE IN)
(Molex M5557-4R Connector, 4
Pins)
−
20 V to
−
60 V/
+
20 V to
+
60 V DC power input
Note: The range of DC power input depends on system
requirement.
Pin 1
0 V*
4
(or +48 V*
5
)
Pin 2
−
48 V*
4
(or 0 V*
5
)
Note: *
4
−
20 V to
−
60 V DC power input.
*
5
+20 V to +60 V DC power input.
FG
Frame ground