OPERATION
3-57
3.4.3 Monitoring the ODU
The following items of the ODU can be monitored on the PC.
• Transmitter output power
• Received signal level
The procedure is as follows:
Step
Procedure
1
Connect the personal computer (PC) to the LA PORT of the
IDU using an RS-232C cable as shown in Fig. 3-7,
2
Turn on the power on the PC. Then, operate the communication
software (e.g. MS Hyper Terminal),
3
Press the “CTRL” and “D” keys at the same time,
4
Enter the specified password from the keyboard and press the
“Enter” key,
5
Press the “0” key and “Enter” key,
6
Following menu items are displayed,
Password
:
Password
:
********
Change password? (no:0 / yes:1) :
1.
Setting
2.
Maintenance
3.
Monitoring
99. Exit
Select function No. :