OPERATION
ROI-S04488
3-30
3.3.2 Shut-down
Step
Procedure
1
Turn off the POWER switch on the front of the IDU.
Note: In 1+1 system, before turn off the POWER switch of No.1
or No. 2 channel, check that the OPR SEL No.1 - No.2
switch is set to channel position to be working.
3.4 Equipment Setting and Monitoring
Test Equipment and Accessories Required
• Personal Computor
• RS-232C cable
• Screw Driver
The control of the IDU and ODU digital radio system can be carried out
via the LA PORT or NMS/RA of the IDU. Connect a Personal Computer
to the IDU with an RS-232C cable. The specifications of the required
communication port condition of the personal computer are listed below.
• Baud rate :
9600
• Data Length :
8
• Parity Check :
None
• Stop bit :
2
• Flow control:
None
• Emulation :
VT100 Video Terminal
• Transmission:
MS Hyper
Terminal*:
Send line ends with line feeds : Yes
Local echo : No
• Receiving:
CR : No
Return on the right edge : Yes
Force incoming data to 7-bit ASCII : No
Notes: 1. MS : Microsoft
* For Windows 95/98/Me/NT4.0/2000/XP
2. When Windows NT4.0 and MS hyper terminal is used,
“Program Download” function is not available.
In this case, please use other terminal software.
(e.g. TeraTerm Pro 2.3:
http://hp.vector.co.jp/authors/VA002416/teraterm.html)