SYSTEM PERFORMANCE
ROI-S04604
3-2
2 pages
Note: * The range of DC power input depends on system requirement.
Frequency
Agility (MHz
without changing
filters)
63
42
56
56-100
252
280
Data signal
interface
Bit rate:
2.048 Mbps ±50 ppm (2
×
2 MB/4
×
2 MB/8
×
2 MB/16
×
2 MB system)
Level:
Meets specification of ITU-T G.703
Code format:
High density bipolar-3 (HDB-3)
Impedance:
75 ohms, unbalanced
120 ohms, balanced
Electro magnetic
compatibility
(EMC)
• ODU/IDU:
ETS300385
Class B
Power
requirement*:
+20 to +60 / -20 to -60 V DC
Power
consumption
4 MB system:
8 MB system:
17 MB system:
34 MB system:
Approx. 50 watts (without optional module)
Approx. 60 watts (equipped with optional module)
Approx. 50 watts (without optional module)
Approx. 60 watts (equipped with optional module)
Approx. 52 watts (without optional module)
Approx. 62 watts (equipped with optional module)
Approx. 55 watts (without optional module)
Approx. 66 watts (equipped with optional module)
Table 3-1 Performance Characteristics (Cont’d)
ITEM
7 GHz
8 GHz
13 GHz
15 GHz
18 GHz
23 GHz
26 GHz
38 GHz
GUARANTEED
Summary of Contents for PASOLINK
Page 1: ...DIGITAL MICROWAVE RADIO SYSTEM PASOLINK Training Course ...
Page 16: ......
Page 17: ...B 1 1 IDU ...
Page 18: ......
Page 68: ...Pasolink Digital microwave radio system Installation guide ...
Page 81: ...NEC PASOLINK installation procedure January 2002 ...