AD-25182501
CHAPTER 3
Page 60
Revision 1.0.1
NAP- 200-005
Sheet 4/4
Connection of Battery
2.
External Battery Connection
When using an external battery, provide the following connections.
Notes:
1. One battery pack is required for each 4-PIM stack, to ensure that sufficient recharge current is
available.
2. The capacity of each external battery is determined by the customers’ back-up requirements.
3.
CAUTION:
For both sealed and vented batteries, set the “mode” switch on the PZ-PW86/PZ-
PW86(A) unit(s) to the correct Float Voltage. The “Equalize” option applies
ONLY
to external
vented
batteries for periodic equalize (BOOST) charging, which can be done on-line. When the
BATTM is used, the battery capacity is in multiples of 26 A-H, up to a maximum of three sets in
parallel for each PIM stack.
.
Figure 005-5: External Battery Connection for 8 PIMs Configuration
–
+
BATT2
BATT1
PZ-PW86
PIM3
BATT2
BATT1
PZ-PW86
PIM2
BATT2
BATT1
PZ-PW86
PIM1
BATT2
BATT1
PZ-PW86
PIM0
BATTERY CABLE
BATT2
BATT1
PZ-PW86
PIM7
BATT2
BATT1
PZ-PW86
PIM6
BATT2
BATT1
PZ-PW86
PIM5
BATT2
BATT1
PZ-PW86
PIM4
BATTERY CABLE
–
+
–
+
12V
26 A-H
–
+
12V
26 A-H
BATTM
(Option)
BATTM
(Option)
PWR
CA-A
CABLE
PWR
CA-A
CABLE
PWR
CA-A
CABLE
PWR
CA-A
CABLE
PWR
CA-A
CABLE
PWR
CA-A
CABLE
12V
26 A-H
12V
26 A-H