AD-25182501
CHAPTER 3
Page 108
Revision 1.0.1
NAP- 200-009
Sheet 1/3
System Initialization and System
ATTENTION
Contents
Static Sensitive
Handling
Precautions Required
Data Entry
1.
System Initialization
• There are two methods for System Initialization. The first method is to Clear All Data, except LEN0000 as
a CAT terminal, and then program the System Data. The second method is to use the Resident System
Program, which causes the system to configure itself automatically to the default settings, wherever the line/
trunk cards are installed. Refer to the System Data Sheet for the default settings.
Turn on the “SW” switch on all the PZ-PW86 power units before initializing anything.
- The “ON” lamp must be lit on all the PZ-PW86 units.
1.1
All Clear, Except LEN0000 CAT
Step 1:
On the MP Card, set SW3 to “B” and press SW1.
Step 2:
When the “MN” lamp on the system is lit, set SW3 to “0” and press SW1.
- Operating mode has been changed to ON LINE.
Note:
Refer to the Circuit Card Manual for information on switch settings.
1.2
Resident System Program
Step 1:
Mount the Line/Trunk cards into PIM.
Step 2:
On the MP Card, set SW3 to “C” and press SW1.
- After 3 to 4 seconds, the “MN” lamp is lit.
- If the “MJ” lamp is lit, repeat the procedure of Step 2.
- The system has loaded the Resident System Program.
Step 3:
Set SW3 to “0” and press SW1.
- Operating mode has been changed to ON LINE.
Note:
Refer to the System Data Sheet for additional information on the Resident System Program and the
initialization of the system without a MAT (enabling CAT mode).