ND-45383 (E)
CHAPTER 5
Page 127
Revision CD 1.0
“13-Q”: DRU Battery Operation
(1) Meaning
The system message “13-Q” means that the AC power supply to the DRU has stopped and thus the DRU is
operating on the battery.
(2) Related System Messages
If the AC power supply has been restored to normal after the system message “13-Q”, the system message “13-
R” is printed out.
(3) Example of Printout
(4) Message Detail Data
(5) Diagnostic from System Message
SYSTEM MESSAGE 13-Q [SUP] DRU BATTERY OPERATION
NEC TOKYO MAY 14 10:30
LP00-0-ACT
1: 0700 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
1: XX 00
Accommodated location of detected DLI card
(Refer to paragraph 2.1.1)
MG: Module Group
U:
Unit
G:
Group
MG
U
G
START
The DRU is not operating on the battery.
END
FAULT : Battery is faulty.
Paragraph 4.3: Battery Fault