CHAPTER 3
ND-45383 (E)
Page 76
Revision CD 1.0
ATTENTION
Contents
Static Sensitive
Handling
Precautions Required
Note 6:
Switch setting for Loop-Back Test
SW3-1
SW3-2
When loop-back test is not performed
:
OFF
OFF
(Normal setting)
When setting the DLI to Local Loop-Back Check
:
ON
OFF
When setting the DLI to Remote Loop-Back
:
OFF
ON
When setting the DLI to Remote Loop-Back Check
:
ON
ON
Note 7:
Switch setting specifying BL lamp indications
SW3-7
SW3-8
The BL lamp indicates the status of No. 0 through
:
OFF
OFF
No. 7 channel
The BL lamp indicates the status of No. 8 through
:
ON
OFF
No. 15 channel
The BL lamp indicates the status of No. 16 through
:
OFF
ON
No. 23 channel
The BL lamp indicates the status of No. 24 through
:
ON
ON
No. 29 channel