![NEC NEAX 2400 ICS Manual Download Page 100](http://html1.mh-extra.com/html/nec/neax-2400-ics/neax-2400-ics_manual_3887361100.webp)
CHAPTER 3
ND-45383 (E)
Page 90
Revision CD 1.0
ATTENTION
Contents
Static Sensitive
Handling
Precautions Required
Note 8:
Switch setting for the PAD value for a case where the line of DLI card is connected via the Network.
SW0-1
SW0-2
0 dB (For in-premise direct installation)
:
OFF
OFF
2 dB
:
ON
OFF
5 dB
:
OFF
ON
8 dB
:
ON
ON
Note 9:
Switch setting for bit rate of D
term
Data Port
SW0-3
SW0-4
64 K (Standard Setting)
:
OFF
OFF
64 K INV
:
ON
OFF
56 K
:
OFF
ON
48 K
:
ON
ON
Note 10:
Switch setting for designating the case where simultaneous communications of voice and APA/APR (Analog
Port Adapter) are performed or the case where the Data Adapter is used. *
SW3-3: for No. 0 ~ 3 circuit
SW3-4: for No. 4 ~ 7 circuit
SW3-5: for No. 8 ~ 10 circuit
SW3-3/3-4/3-5
When simultaneous communications of voice and APA/APR
ON
(Analog Port Adapter) are performed.
(In this case, the Data Adapter cannot be used.)
When the Data Adapter is used.
OFF
*This switch setting is effective when using DRU-23-S3 by 11DLC + 1ELC mode. When DRU-23-S3 is used
by 23ELC mode, set these switches to OFF.
SYMBOL
CIRCUIT CARD
DLI
PA-DAIC