6. Error Messages
Express5800/R320d-E4, R320d-M4 Maintenance Guide (VMware 5.5)
59
Chapter 1 Maintenance
(2)
Error messages on a virtual LCD
In EXPRESSSCOPE Engine 3 web browser window, you can confirm virtual LCD error messages (for details on
the virtual LCD, refer to "EXPRESSSCOPE Engine 3 User’s Guide").
The table below shows the error messages displayed on upper and lower lines, cause, and solution.
Messages displayed on an upper LCD line
Message
on Upper LCD Line
Description
Solution
XXXX BIOSXXXX
Displayed while POST is running.
This is not an error.
POST Completed
Successfully
Displayed when POST completes normally.
This is not an error.
POST ERROR
XXXX
Error XXXX was detected during POST.
Check the message displayed on LCD, and take an
appropriate action.
System Simplex
The system is operating in simplex mode.
This is not an error.
System Duplex
CPU/IO module is operating in duplex
mode.
This is not an error.
Split mode
CPU/IO module is operating in split mode.
This is not an error.
CPU Broken
A CPU failure was detected.
Contact your sales representative.
IO Broken
An I/O unit failure was detected.
Contact your sales representative.
Message displayed on upper
LCD line
Message displayed on lower
LCD line