2. Disk Operations
Express5800/R320d-E4, R320d-M4 Maintenance Guide (VMware 5.5)
101
Chapter 2 Configuring and Upgrading the System
2.5
Adding Hard Disk Drives
To add hard disk drives, follow the steps below. The hard disk drives should be added with the power of the
CPU/IO module 0 and 1 turned on.
2.5.1
Inserting Additional Disk Drives
Insert additional disk drives into empty slots in the order of the slot number from lowest to highest. Note that
two disks should be inserted into the correct locations to become a pair of slots that supports the mirroring
process.
2.5.2
Configuring a RAID Device
This section describes how to configure a new RAID device on the added disks.
Important These operations must be performed by the root user.
Note
If the target disk drive has a data contained in it, the existing data will be erased by
configuring RAID system. Make sure that the target disk drive does not contain any
necessary data.
1. Run esxcli -s <
ESXi host IP address
> storage mpm list.
2. Check the added disks in the information displayed.
The following is an example that two disks are inserted into a pair of slots for the slot 1.
# esxcli –s xxx.xxx.xxx.xxx storage mpm list
Info
------------------------------------------------------
mpm0 : 143066368 blocks (139713 MB) [2/2]
\_ vmhba0:C0:T0:L0 (10/40/1) [ in_sync ]
\_ vmhba1:C0:T0:L0 (11/40/1) [ in_sync ]
Unused disks:
- vmhba0:C0:T1:L0 (10/40/2)
- vmhba1:C0:T1:L0 (11/40/2)