Chapter 10 Troubleshooting
Event ID280 (spsdsm) is generated
in the system event log.
Check if the configuration of connections between the
servers and the disk array unit has been changed due to an
event such as replacement of an HBA or reconnection of an
FC cable. Delete the old configuration information by
running
spsadmin/deletemissing
.
Event ID10 (WinMgmt/WMI) is
generated in the application event
log.
This event is generated due to the specification of the SPS,
and is not indication of abnormality. This does not affect the
operation of the system.
Source: WinMgmt (Case of Windows Server 2003)
WMI (Case of Windows Server 2008)
EventID: 10
Type: Error
Description:
Event filter with query "
select * from
SPN_EVENTENTRY
" could not be (re)activated in
namespace "//./root/WMI" because of error 0x80041010.
Events may not be delivered through this filter until the
problem is corrected.
Or,
Event filter with query "
select * from
NEC_MAM_EVENTENTRY
" could not be (re)activated in
namespace "//./root/WMI" because of error 0x80041010.
Events may not be delivered through this filter until the
problem is corrected.
Problem
Cause and Solution
Summary of Contents for M100
Page 25: ...Release 6 0 25 User Guide About Warning Labels Power Supply AC Power Supply ...
Page 27: ...Release 6 0 27 User Guide About Warning Labels Battery ...
Page 29: ...Release 6 0 29 User Guide About Warning Labels Power Cable AC Power Supply ...
Page 40: ...Release 6 0 40 User Guide Chapter 1 Overview 1 2 1 4 Controller CONT ...
Page 48: ...Release 6 0 48 User Guide Chapter 1 Overview 1 2 3 3 Controller CONT ...
Page 260: ...Release 6 0 260 User Guide Chapter 8 Installing Optional Parts Figure 8 12 Removing the DIMMs ...
Page 459: ...NEC Corporation 7 1 Shiba 5 chome Minato ku Tokyo 108 8001 Japan URL http www necstorage com ...