1. Installing Internal Optional Devices
Express5800/R120g-2E User's Guide
90
Chapter 2 Preparations
Priority
Product
number
Slot number
PCI #1
(2 CPUs
required)
PCI #2 PCI #3 PCI #4 PCI #5
Remarks
PCI standard
PCIe 3.0
PCIe
2.0
PCI slot performance
x8
lane
x16
lane
x8
lane
x16
lane
x4
lane
Socket type
x8
socket
x16
socket
x8
socket
x16
socket
x8
socket
Transfer bandwidth
(per lane)
8Gb/s 5Gb/s
Slot size
Low Profile
Available card size
168mm
max.
200mm max.
168mm
max.
Product
name
High N8104-153 10GBASE-T Adapter (2ch)
(PCI Express 2.0(x8))
(4) (2) (1) (3) (5)
For additional LAN
port.
Up to three N8104-149,
N8104-153 and
N8104-157 cards can be
mounted in total in
1-CPU configuration.*1
Up to five N8104-149,
N8104-153 and
N8104-157 cards can be
mounted in total in
2-CPU configuration.*1
N8104-149 10GBASE
Adapter
(SFP+/2ch)
(PCI Express 2.0(x8))
(4) (2) (1) (3) (5)
For additional LAN
port.
Prepare SFP+module
N8104-129 if needed.
N8103-142 SAS
Controller
(PCI Express 2.0(x8))
(4) (2) (1) (3) (5)
For connecting with
external devices
N8103-184 and
N8103-142 can be
mounted up to three
cards in total
N8104-152 1000BASE-T Adapter (4ch)
(PCI Express 2.0(x4))
(4) (2) (1) (3) (5)
For additional LAN port.
LAN cable with boots cannot be used.
N8104-145 1000BASE-T Adapter (2ch)
(PCI Express 2.0(x4))
(4) (2) (1) (3) (5)
For additional LAN port.
N8104-151 1000BASE-T Adapter (2ch)
(PCI Express 2.0(x1))
(4) (2) (1) (3) (5)
For additional LAN port.
Card type: PCI Express 2.0 (x4)
N8104-150 1000BASE-T Adapter (1ch)
(PCI Express 2.0(x1))
(4) (2) (1) (3) (5)
For additional LAN port.
Card type: PCI Express 2.0 (x4)
Low
N8117-01A Additional RS-232C connector
-
-
(1) (2) (3)
For additional serial port B (RS-232C).
Only one card can be mounted.
Note
PCI cards are listed in order of priority for mounting in slots. Numbers in parentheses indicate the priority of each slot for each card.
If "–" is displayed, the card cannot be mounted.
Example: Suppose you want to mount a N8103-176 RAID Controller (1GB, RAID 0/1), N8190-158A Fibre Channel Controller (2ch)
(16Gbps/Optical), and N8103-142 SAS Controller. Select the controller to be mounted first based on the card priority, and then select
the slot to mount the card based on the slot priority. In this case, the controllers should be mounted in the following order:
RAID Controller to #3 (the highest priority), Fiber Channel Controller-#2 (#3 is already used), SAS Controller - #4 (#3 and #2 are
already used)
*1 Performance of LAN depends on the application and memory capacity. If you want to mount three or more 10G LAN cards, a
sufficient verification under your system environment is needed.