![NEC Express5800/R120i-2M Installation Manual Download Page 97](http://html2.mh-extra.com/html/nec/express5800-r120i-2m/express5800-r120i-2m_installation-manual_4811566097.webp)
1. List of Windows Event Logs
Installation Guide (Windows Server 2019)
97
Chapter 3 Appendix
ID
Source
Level
Message (Description)
Timing when an event is logged
Action
Windows Server 2019 ”System Log”
219
Kernel-PnP
Warning
The driver \Driver\q57nd60a failed to load for the device
PCI\VEN_xxxx&DEV_xxxx&SUBSYS_xxxxxxxxxxxx.
* x is a different display name depending on the LAN board.
When installing an OS with Rapid Setup
This event does not affect system operation.
225
Kernel-PnP
Warning
The application YYY with process id XXX stopped the removal or
ejection for the device ZZZ.
* ZZZ : Instance name of the device
YYY : Name of the process that was using the device
XXX : ID of the process that was using the device
When applying
Standard Program Package
This event does not affect system operation.
260
Microsoft-Windows-Hyper-V-
VmSwitch
Error
Failed to move RSS queue xx from VMQ xx of switch
xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx (Friendly Name: xx),
ndisStatus = -1071448015 .
When starting system, or starting virtual
machine
This event does not affect system operation.
262
icea
Error
Intel(R) Ethernet Network Adapter E810-XXV-2 xxx
PROBLEM: Module is not present.
Possible Solution(s):
Manually set the speed/duplex or use Intel(R) Ethernet Port
Configuration Tool to change the port option.
If the problem persists, use a cable/module that is found in the
supported modules and cables list for this device.
* "x" depends on the optional LAN board environment.
When SFP+/SFP28 module (N8104-189/
190) or DA cable disconnected from
optional LAN board (N8104-208/212).
Confirm the SFP+/SFP28 module (N8104-189/190) or DA cable.
272
icea
Error
Intel(R) Ethernet Network Adapter E810-XXV-2 xxx
PROBLEM: A parallel fault was detected.
Possible Solution: Change link partner connection and configuration.
* x is a different display name depending on the LAN board.
When SFP+/SFP28 module (N8104-189/
190) or DA cable is connected to the LAN
board (N8104-208/212) and the network
link is down.
Applying Standard Program Package.
This event does not affect system operation.
7023
Service Control Manager
Error
"xxxxxxxx service terminated with the following error:
A device attached to the system is not functioning."
When running an OS for the first time
This event does not affect system operation if it is recorded only on
the first startup and not recorded repeatedly.
7023
Service Control Manager
Error
The Spooler service terminated with the following error:
Ran out of memory
When installing an OS
There is no problem when it occurs at following conditions.
1. Occurs once during OS installation, and it does not register
continuously.
2. After sign-in to the system, the service started normally.