1. List of Windows Event Logs
Installation Guide (Windows Server 2019)
90
Chapter 3 Appendix
ID
Source
Level
Message (Description)
Timing when an event is logged
Action
All Windows OS ”System Log”
56
Application Popup
Error
The description for Event ID 56 from source Application Popup
cannot be found. Either the component that raises this event is not
installed on your local computer or the installation is corrupted. You
can install or repair the component on the local computer.
If the event originated on another computer, the display information
had to be saved with the event.
The following information was included with the event:
PCI
XXXXXXXXXXXXXXXXX
The message resource is present but the message was not found
in the message table.
* A different number replaces X depending on the connection status
of LAN controller.
When installing an OS, starting system, or
applying Starter Pack
When multiple LAN controller are loaded it is registered, but does
not affect system operation.
56
Application Popup
Error
The description for Event ID 56 from source Application
Popup cannot be found. Either the component that raises
this event is not installed on your local computer or the
installation is corrupted. You can install or repair the
component on the local computer.
If the event originated on another computer, the display
information had to be saved with the event.
The following information was included with the event:
SCSI
XXXXXXXXXXXXXXXXX
The message resource is present but the message was not
found in the message table.
* A different number replaces X depending on the
connection status of RAID controller and SAS controller.
When installing an OS, starting system, or
applying Starter Pack
When multiple RAID controller or SAS controller are loaded it is
registered, but does not affect system operation.
129
SmartDQa
Warning
Reset was issued to the device \Device\RaidPort(x).
(x is any number)
While the system is running
If this message has been registered as a log during heavy I/O,
there is no problem since the OS has succeeded in retry. Continue
using.
129
SmartPqi
Warning
Reset was issued to the device \Device\RaidPort(x).
(x is any number)
While the system is running
Even if the message is registered in the log, there is no problem
because the OS has successfully completed the retry. You don't
need any changes.