1. POST Error Message
Express5800/R120g-2E, T120g Maintenance Guide
204
Chapter 3 Appendix
Error Message
Cause
Solution
C301
SDR mismatch error
Inconsistency in the hardware
information of the sensor data
record was detected
Contact your sales representative.
C302
Hardware configuration
error.
Illegal hardware configuration
was detected.
C303
FAN Structure ID command
error.
Illegal fan control was detected
when RAID controller is
installed.
C304
Necessary to update SDR
Version for new RAID Card.
SDR for RAID controller is
inappropriate.
C310 Hardware configuration of
cooling is insufficient.
Detected that cooling power is
insufficient in this hardware
configuration.
C320 Unmatched PSUs.
Unmatched power supply units
are configured.
C321 System power consumption is
out-of-range in PSUs.
System power consumption
exceeds the power output
capacity limit.
C322 No information for system
power consumption check.
No information is acquired in
checking system power
consumption.
C323
Internal Use Area of BMC FRU is
incompatible.
FRU containing the device
information is unmatched.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same error
is detected repeatedly, contact your sales
representative.
C501 ME is in Recovery Mode.
Intel Node Manager is in
Recovery Mode.
Unplug the power cord, wait for at least 30
seconds, then restart the server. At that time,
check the jumper switch setting on motherboard.
If the same error is detected repeatedly, contact
your sales representative.
C600
Internal Flash is not valid.
Internal Flash Memory was
specified by a one-time boot
device but could not be
enabled.
Unplug the power cord, wait for at least 30
seconds, and then restart the server.
If the same error is detected repeatedly, contact
your sales representative.
C624
Invalid internal BIOS
Configuration Data.
Internal error of BIOS
Configuration Data was
detected.
C625
BIOS Configuration Data Send
Error.
This is an error when BIOS
Configuration Data is sent.
C626
BIOS Configuration Data Read
Error.
This is a read error on BIOS
Configuration Data.
C627
BIOS Configuration Data Write
Error.
This is a write error on BIOS
Configuration Data.
C628
System configuration data
cleared by System Boot Options
command.
The SETUP settings were
cleared by the standard
IPMI-compliant command of
“Set System Boot Options.”
Run SETUP and re-specify each item.
If the problem cannot be solved, contact your
sales representative.
Summary of Contents for Express5800/R120g
Page 231: ...MEMO...