1. POST Error Message
Express5800/R120f-1M, R120f-2M Maintenance Guide
149
Chapter 3 Appendix
Error Message
Cause
Solution
C10C
BMC update firmware
corrupted.
An illegality was detected while
updating BMC firmware.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same error
is detected repeatedly, contact your sales
representative.
C10D
Internal Use Area of BMC FRU
corrupted.
An illegality was detected in
FRU containing the device
information.
C10E
BMC SDR Repository empty.
An error was detected on BMC
SDR.
C10F
IPMB signal lines do not
respond.
Failure of Satellite Management
Controller was detected.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same error
is detected repeatedly, contact your sales
representative.
C110
BMC FRU device failure.
An error was detected in FRU
that contains device
information.
C111
BMC SDR Repository failure.
Failure was detected in SROM
that stores the SDR.
C112
BMC SEL device failure.
Device failure was detected in
BMC SEL.
C113
BMC RAM test error.
An error was detected in BMC
RAM.
C114
BMC Fatal hardware error.
A hardware error was detected
in BMC.
C115
Management controller
not responding
Management controller does
not respond.
Update the BMC firmware.
If the same error is detected repeatedly, contact
your sales representative.
C116
Private I2C bus not
responding.
Private I2C bus does not
respond.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same error
is detected repeatedly, contact your sales
representative.
C117
BMC internal exception
BMC internal error was
detected.
C118
BMC A/D timeout error.
BMC A/D timeout error was
detected.
C119
SDR repository corrupt.
BMC error or illegal SDR data
was detected.
C11A
SEL corrupt.
BMC error or illegal system
event log data was detected.
C11B
BMC Mezzanine card is not
found.
BMC Mezzanine card is not
installed.
Contact your sales representative.
C11C
BMC Mezzanine partition is
invalid.
A format error was detected in
BMC Mezzanine card.
C11D
BMC is in Forced Boot Mode.
Detected that BMC is in Forced
Boot Mode.
Unplug the power cord, wait for at least 30
seconds, then restart the server. At that time,
check the jumper switch setting on motherboard.
If the same error is detected repeatedly, contact
your sales representative.
C11E
Communication with BMC was
failed in previous boot
Communication with BMC was
failed in previous boot
Unplug the power cord, wait for 30 seconds, and
reboot the server. If the same error is detected
repeatedly, contact your service representative.
C11F
Backup Data of BMC Mezzanine
card has corrupted.
Inconsistency was found on
BMC mezzanine card.
Contact your service representative.
C120
BMC Runtime FW corrupted.
An error occurred on BMC
Runtime FW.
Disconnect the power cord, wait for at least 30
seconds, and then reboot the system. If the same
error is detected again, contact your maintenance
service company.
C121
BMC Force Update FW corrupted.
An error occurred on BMC
Force Update FW.
C122
BMC Configuration area
corrupted.
An error occurred on BMC
Configuration area.
C123
BMC eMMC inaccessible.
Failed to access to BMC
eMMC.
C125
BMC eMMC mode error.
BMC eMMC mode error
C126
BMC eMMC partition corrupted.
An error occurred on BMC
eMMC partition.
C127
BMC eMMC format corrupted.
A format error occurred on BMC
eMMC.
C128
BMC is in Update Mode.