1. POST Error Message
Express5800/R110i-1, T110i-S, T110i Maintenance Guide
194
Chapter 3 Appendix
(5/5)
Error Message
Description
Action
C127
BMC eMMC format corrupted.
A format error occurred on BMC
eMMC.
Turn off the power, disconnect the server from the
outlet, wait for at least 30 seconds, and restart the
server.
C128
BMC is in Update Mode.
BMC is in update mode.
C200
The error occurred during
memory configuration check.
The memory information could not
be obtained.
Turn off the power and restart the server.
C201
Memory Configuration change
is detected.
The memory configuration has
changed since the previous
startup.
When
Check previous system Config
is
enabled in
server
of the BIOS settings, this
message appears if the configuration was
changed since the previous startup. If this
message appears even when no configuration
change has been made, contact your sales
representative.
C202
The error occurred during
CPU configuration check.
The CPU information could not be
obtained.
Turn off the power and restart the server.
C203
CPU Configuration change is
detected.
The CPU configuration has
changed since the previous
startup.
When
Check previous system Config
is
enabled in
server
of the BIOS settings, this
message appears if the configuration was
changed since the previous startup. If this
message appears even when no configuration
change has been made, contact your sales
representative
C300
Out-of-band setup
configuration failure
Invalid access to BMC Mezzanine
card
Contact your sales representative.
C321
System power consumption is
out-of-range in BBUs
Over capacity of system power
capacity.
C501
Intel(R) Node Manager is in
Recovery Mode
The Recovery Mode of Intel Node
Manager was detected.
Check the jumper switch on the motherboard.
Unplug the power cable, wait for at least 30
seconds, and then restart the server.
C600 Internal
Flash is not valid.
Selected Internal Flash Memory
as an onetime booting device but
unable to enable it.
Turn off the power, disconnect the server from the
outlet, wait for at least 30 seconds, and restart the
server.
C624
Invalid internal BIOS
Configuration Data.
Internal error of BIOS
Configuration Data was detected.
C625
BIOS Configuration Data Send
Error.
An internal error was detected
during sending BIOS
Configuration Data.
C626
BIOS Configuration Data Read
Error.
An internal error was detected
during reading BIOS Configuration
Data.
C627
BIOS Configuration Data
Write Error.
An internal error was detected
during writing BIOS Configuration
Data.
C628
System configuration data
cleared by System Boot
Options command.
The SETUP setting was cleared
by Set System Boot Options of the
standard IPMI command.
Run SETUP, and then specify the necessary
settings.