2. Server Configuration
Express5800/R110i-1, T110i-S, T110i Maintenance Guide
121
Chapter 2 Useful Features
List of items in Battery Information (2/2)
Item Description
Battery Controller Information
Manufacture Name
Displays manufacturer name of the battery controller.
Device Name
Displays device name of the battery controller.
Firmware Revision
Displays firmware revision of the battery controller.
Supported Battery Type
Displays battery type supported by the battery controller.
Approximate Backup Time at
Full Charge (current load)
Displays approximate backup time (minutes : seconds) that
shows how many minutes the battery controller is able to
supply power from fully charged state with current system
load.
*2 *3
Approximate Backup Time at
Full Charge (maximum load)
Displays approximate backup time (minutes : seconds) that
shows how many minutes the battery controller is able to
supply power from fully charged state with maximum system
load.
*2 *3
Rated Capacity
Rated Capacity Displays rated capacity (mAh) of the battery
controller.
Rated Power
Rated Power Displays rated power (Watts) of the battery
controller.
Peak VA
Peak VA Displays peak power (Watts) of the battery controller.
Charge Power
Charge Power Displays charge power (Watts) of the battery
controller.
*1: If the battery pack is not mounted, "-" is displayed.
*2: If the approximate backup time is uncertain, "-" is displayed.
*3:
Approximate Backup Time at Full Charge
is reference value of estimated operating time. Actual operating time may differ
depending on ambient temperature and the other conditions.
Battery Controller Configuration
2.7.2
Described below is details of the items to be displayed when you select Battery Controller Configuration in
battery configuration menu.
List of items in Battery Controller Configuration
Item Description
Default
value
Battery Controller Configuration
Shutdown at power lost
Selects enable/disable shutdown at power lost.
*1
Enable
Shutdown delay time
Specifies waiting time (seconds) for starting shutdown at
power lost.
*2 *3
30
Battery turn off delay time
Specifies waiting time (seconds) for finishing shutdown at
power lost.
*2 *3
3600
Boot after power recovery
Selects enable/disable startup after power supply restored.
*2 *4
Enable
Boot timeout after DC-ON
Specifies waiting time (seconds) for finishing startup after
DC-ON.
*2 *3 *5
0
*1: To perform shut down, you have to configure the setting to perform shut down when the power button of the device is
pressed.
*2: This can be set only when Shutdown at power lost is set to "Enable".
*3: Output may be stopped earlier than each time you set depending on remaining capacity of the battery.
*4: This setting is available in case of AC-LINK setting is Stay Off, or AC-Link setting is Last State and the device is DC-OFF.
*5: Available at DC-ON after DC-OFF by Shutdown at power lost feature. (Available at DC-ON by Boot after power recovery
feature or DC-ON by hand.)