1. Installing Internal Optional Devices
Express5800/GT110d User’s Guide
49
Chapter 2 Preparations
1.7.4
Removal
Remove a DIMM in the following procedure.
Note
When removing a defective DIMM, check error messages displayed at POST or
ESMPRO and check the DIMM slot where the defective DIMM is installed.
At least one DIMM needs to be installed for the server to operate.
1.
Refer to steps 1 to 5 in
Chapter 2 (1.3 Overview of Installation and Removal
for preparations.
2.
Rotate both levers of the target DIMM
slot outward.
The DIMM is unlocked
3.
Remove the DIMM by pulling it out from
the slot in a straight direction.
Important
Applying too much pressure on a DIMM or pulling a DIMM at an angle may
break the DIMM or slot. Gently pull it straight out of the slot.
4.
Assemble the server.
5.
Turn on the server and confirm that no error messages are displayed on POST. If any error message
is displayed, refer to
Chapter 3 (1. Post Error Message)
in "
Maintenance Guide
".
6.
If you replaced a broken DIMM, select
Yes
in
Memory Configuration
-
Memory
Retest
of the
Advanced
menu.
After that, select
Save Changes and Exit
to reboot.
7.
If an OS has been installed, change the paging file size.
If your OS is Windows, refer to “
Installation Guide (Windows)
”.