![NEC ExpEther-2S User Manual Download Page 83](http://html.mh-extra.com/html/nec/expether-2s/expether-2s_user-manual_251145083.webp)
63
Level
Log message
description
ERROR
The active driver is not found.
Indicates failure to search ExpEther
devices as the PlxSvc driver has not
been installed or is invalid.
ERROR
Failed to scan devices.
Indicates failure to scan PCI devices.
ERROR
Failed to write model name (offset : xx,
value :xx).
Indicates failure to write the model
name.
ERROR
Failed to write serial number (offset : xx,
value :xx).
Indicates failure to write the serial
number.
ERROR
Failed to open device
Indicates failure to open devices.
ERROR
Failed to read model name (offset : xx).
Indicates failure to read the model
name.
ERROR
Failed to read serial number (offset : xx). Indicates failure to read the serial
number.
ERROR
Device is busy.
Indicates failure to access EEPROM.
ERROR
Compare error (write data: xx, read
data: xx)
Indicates the data to write to EEPROM
did not correspond to the read data.
ERROR
Failed to write register (offset: xx, value:
xx, err: xx)
Indicates failure to write registers.
ERROR
Failed to write register (offset: xx, err:
xx)
Indicates failure to read registers.
ERROR
Failed to get the host data.
Indicates failure to get the host
information.
ERROR
Failed to read MAC address from
eeprom (offset: xx).
Indicates failure to read the MAC
address.
ERROR
Failed to read VLAN ID from eeprom
(offset: xx).
Indicates failure to read VLAN ID.
ERROR
Exceeded the retry count to lock
EEPROM access.
Indicates failure to lock EEPROM
access.
ERROR
Exceeded the retry count to verify the
lock for EEPROM access.
Indicates failure to verify the lock for
EEPROM access.
ERROR
Exceeded the retry count to unlock
EEPROM access.
Indicates failure to unlock EEPROM
access.
ERROR
Exceeded the retry count to read
register with indirect access.
Indicates failure to read registers with
indirect access.
ERROR
Exceeded the retry count to write
register with indirect access.
Indicates failure to write registers with
indirect access.
Important After executing the command “set_hostinfo” and setting the host
information, be sure to execute the CLI subcommand “audit” of
ExpEther Manager.
eemcli.py audit --id ID
Important Do not execute this tool several times at a time.
Tip
If you find an error caused by the tool due to a failure in locking, wait for
several seconds or several ten seconds and execute it again. If the error
persists, execute the CLI subcommand “unlock_eeprom” of ExpEther
Manager.
eemcli.py unlock_eeprom --id ID
Tip
An old version of the PlxSvc driver may have the ExpEtherConfig tool
cause an error. In that case, delete the PlxSvc driver in advance and
install the ExpEtherConfig tool again.