5. Steps to upgrade to 4K
176
Error code
Error message
Description
337
Red Satellite Firmware Configuration Error
ICP board error
338
Red DAD1000 Bias Under Voltage Error
ICP board error
339
Red DAD1000 Reset Under Voltage Error
ICP board error
340
Red DAD1000 Offset Under Voltage Error
ICP board error
341
Red DAD1000 Thermal Shutdown Error
ICP board error
342
Green Satellite Reports Reset
ICP board error
343
Green Satellite Serial Link Error
ICP board error
344
Green Satellite Firmware Configuration Error ICP board error
345
Green DAD1000 Bias Under Voltage Error
ICP board error
346
Green DAD1000 Reset Under Voltage Error
ICP board error
347
Green DAD1000 Offset Under Voltage Error
ICP board error
348
Green DAD1000 Thermal Shutdown Error
ICP board error
349
Blue Satellite Reports Reset
ICP board error
350
Blue Satellite Serial Link Error
ICP board error
351
Blue Satellite Firmware Configuration Error
ICP board error
352
Blue DAD1000 Bias Under Voltage Error
ICP board error
353
Blue DAD1000 Reset Under Voltage Error
ICP board error
354
Blue DAD1000 Offset Under Voltage Error
ICP board error
355
Blue DAD1000 Thermal Shutdown Error
ICP board error
356
RTC Error
Indicates that ICP RTC is set to a date
before January 1, 2009, and is likely
invalid. If the year value is less than 2009,
then the time is considered to be "invalid".
400
Enigma Comm Fail
No communication with the Enigma board.
410
System Error
Enigma Status error
411
Self Test Error
Enigma Status error
412
Install Release Package Error
Enigma Status error
413
Load Release Package Error
Enigma Status error
414
TI Login List Package Error
Enigma Status error
415
Security Officer Login List Package Error
Enigma Status error
419
Certificate or Key Error
Enigma Status error
420
ICP Communications Status
Enigma fails to do logical marriage to ICP
when Enigma powers up. Because of no
communications with ICP during logical
marriage.
426
User Loader Integrity Error
Enigma is in FIPS error state. (Integrity
check error)
427
Main Application Integrity Error
Enigma is in FIPS error state. (Integrity
check error)
428
RNG Hardware Integrity Error
Enigma is in FIPS error state. (Integrity
check error)
429
DRNG Algorithm Integrity Error
Enigma is in FIPS error state. (Integrity
check error)
430
RSA Algorithm Integrity Error
Enigma is in FIPS error state. (Integrity
check error)
431
AES Algorithm Integrity Error
Enigma is in FIPS error state. (Integrity
check error)
432
HMAC Algorithm Integrity Error
Enigma is in FIPS error state. (Integrity
check error)
433
SHA Algorithm Integrity Error
Enigma is in FIPS error state. (Integrity