Program Execution Start and Stop
92
10 Program Execution Start and Stop
The program execution is started by the use of the START
button.
The program execution can be stopped by means of the following functions and keys:
– with the STOP
button,
– with the RESET
key,
– at the end of block execution in the single block mode
,
– after executing programmed stop command
M00
,
– as the effect of conditional stop command
M01
, if optional stop switch
is on,
– after executing program end commands
M02, M30
.
10.1 Starting Program Execution
In the following cases the program execution is started by pressing START button
:
– in jog, incremental jog or manual handle feed mode, after single block has been entered and
terminated,
– in automatic mode, if program is selected for execution from memory or DNC,
– in manual data input mode, if program is selected for execution.
Error message
NOT EXISTING PROGRAM
is displayed by pressing START button, if no program is selected for execution. START state
is indicated by caption
STRT
in the 3
rd
field of status bar.
10.2 Feed Stop
During program execution by pressing STOP button
START state is cancelled. The
axes decelerate and stop. The execution of functions (M, S, T, B) in the given block is
continued till the end of block. STOP state is indicated by caption
STOP
in the 3
rd
field of the
status bar.
In the following cases the STOP button is ineffective:
– G63, i.e. state of override inhibit,
– values of variable #3004 listed in programmer’s manual, and
– during thread cutting G33, G34 and tapping cycles G84.1, G84.
10.3 RESET
If reset key
is pressed during
program execution
, START or STOP state is canceled.
The axes decelerate and stop, even if control executes operation, where the use of feedrate
override switches and STOP button is ineffective (e.g.: G33, G34, G76, G78, G84.1, G84).
Summary of Contents for 100T