14.3
Listing of Global Messages
Error
Code
Message
Description
Canceling and Re-
pairing Method
137
3086
DEFINITION ERROR G51
If scaling axis by axis is programmed
(G51 X Y Z I J K) and X and U, or Y and
V, or Z and W are in one block.
The message is can-
celed by RESET
key.
3087
ILLEGAL PLANE SELECT
If in G76 multiple thread cutting cycle, on
lathe control, not G18 plane is selected.
The message is can-
celed by RESET
key.
3088
FORBIDDEN SPINDLE
MOVING
If no spindle encoder is on the machine
and an instruction demanding spindle en-
coder has been programmed (e.g. thread
cutting, orientation).
The message is can-
celed by RESET
key.
3089
BUFFER OVERRUN G41,
G42
If buffer has been overrun in offset mode
(G41, G42).
The message is can-
celed by RESET
key.
3090
# DEFINITION PROHIB-
ITED
Defining prohibited macro variable (#....).
This may be due to its type (e.g., #1000,
... #1015), or it may be prohibited at
parameters 9101 WRPROT1, 9102
WRPROT2.
The message is can-
celed by RESET
key.
3091
ERRONEOUS OPERATION
WITH #
If, in case of macro variables (#...), the
operands and operations conflict. E.g.: if
logical addition (AND) has been com-
manded between macro variables that can-
not be represented in 32 bits in fix point
mode.
The message is can-
celed by RESET
key.
3092
DIVISION BY 0 #
If, in case of evaluating a macro
expression, division is to be done by 0.
The message is can-
celed by RESET
key.
3093
BUFFER OVERRUN #
Buffer has been overrun with macro vari-
ables.
The message is can-
celed by RESET
key.
3094
3095
3096
3097
3098
ERRONEOUS ARGUMENT
If the function value exceeds the range.
If e.g., SQRT[-4] or ASIN[2]),
if, in case of instruction BCD, the
transformed number is of more than 8
digits,
if, in case of instruction BIN, not a BCD
number is defined on the decades.
The message is can-
celed by RESET
key.
3099
Summary of Contents for 100T