14.3
Listing of Global Messages
Error
Code
Message
Description
Canceling and Re-
pairing Method
128
1340
LIMIT t+
This message is displayed, if one of the
axes has run on limit switch or on overtra-
vel position specified at a parameter in
direction –.
Value of t is the name of the axis: X, Y,
Z, U, V, W, A, B, C.
In the error code (1360, 1361, 1362, ...)
the digit on local value 1 (0, 1, 2, ...) +1 is
the physical axis number.
The error can be can-
celed only by moving
the axes away from
the overtravel posi-
tion by means of
manual intervention.
1341
1342
1343
1344
1345
1346
1347
1360
LIMIT t–
This message is displayed, if one of the
axes has run on limit switch or on overtra-
vel position specified at a parameter in
direction –.
Value of t is the name of the axis: X, Y,
Z, U, V, W, A, B, C.
In the error code (1360, 1361, 1362, ...)
the digit on local value 1 (0, 1, 2, ...) +1 is
the physical axis number.
The error can be can-
celed, only by mov-
ing the axes away
from the overtravel
position by means of
manual intervention.
1361
1362
1363
1364
1365
1366
1367
1380
SPINDLE LOOP OPEN
This message is displayed, if spindle in-
dexing has been commanded on address C
or by M function and orientation M19 has
not been programmed previously.
The message is can-
celed by RESET
key.
1400
INTERNALLY FORBID-
DEN AREA
This message is displayed by the NC, if an
internally forbidden area has been speci-
fied by means of command G22, and one
of the axes runs on the limit of this area,
or is in the forbidden area at the moment
of specification.
The error can be can-
celed only if the axes
are moved away from
the zone limit by
means of manual
intervention. If in the
moment of selection
one of the axes is in
the forbidden area,
first the specification
must be canceled by
means of command
G23.
Summary of Contents for 100T
Page 143: ...Notes 143 Notes ...