14.3
Listing of Global Messages
Error
Code
Message
Description
Canceling and Re-
pairing Method
126
1102
REFERENCE POINT t3
This message is displayed, if the zero
pulse has not been found after leaving the
reference switch within the distance spec-
ified at parameter
SWSHIFT
+
:
ZEROD-
IS.
Value of t is the name of the axis: X, Y,
Z, U, V, W, A, B, C.
In the error code (1102, 1112, 1122, ...)
the digit on local value 10 (0, 1, 2, ...) +1
is the physical axis number.
The message is can-
celed by RESET
key.
1112
1122
1132
1142
1152
1162
1172
1103
REFERENCE POINT t4
If during the reference point return zero
pulse is found, the axis changes its direc-
tion and searches for it again in the new
direction at a lower speed. If this time it
cannot find the zero pulse within 1000 in-
crements, this message is displayed.
Value of t is the name of the axis: X, Y,
Z, U, V, W, A, B, C.
In the error code (1103, 1113, 1123, ...)
the digit on local value 10 (0, 1, 2, ...) +1
is the physical axis number.
The message is can-
celed by RESET
key.
1113
1123
1133
1143
1153
1163
1173
1104
REFERENCE POINT t5
This message is displayed, if during the
reference point return zero pulse is found
after running off the switch within the dis-
tance specified at parameter
SWSHIFT
+
3
ZERODIS.
Value of t is the name of the axis: X, Y,
Z, U, V, W, A, B, C.
In the error code (1104, 1114, 1124, ...)
the digit on local value 10 (0, 1, 2, ...) +1
is the physical axis number.
The message is can-
celed by RESET
key.
1114
1124
1134
1144
1154
1164
1174
Summary of Contents for 100T