14.3
Listing of Global Messages
Error
Code
Message
Description
Canceling and Re-
pairing Method
124
60
PLC TIMEOUT 1
If either module :001 or module :002 of
PLC program does not expire in the time
slice reserved for it, message PLC TIME-
OUT 1 or 2 is displayed.
This message is generated in EMG state.
This message can
only be canceled by
power-off of the con-
trol. In order to
repair it, turn to a
well-trained expert.
61
PLC TIMEOUT 2
70
DPG TIMEOUT
If the interpolation cycle does not expire
in the time slice reserved for it, message
DPG TIMEOUT is displayed.
This message is generated in EMG state.
This message can
only be canceled by
power-off of the con-
trol. In order to
repair it, turn to a
well-trained expert.
80
15V FAILURE
If the comparator circuit detects that the
specified voltage is not available at the
+/–15V output of power supply, message
15V Failure is displayed.
This message is generated in EMG state.
This message can
only be canceled by
power off of the con-
trol. In order to
repair it, turn to a
well-trained expert.
90
SYNC. FAILURE 1
If the movement of two axes is synchro-
nized (gantry axes) and the position
deviation value of the two axes is larger
than the value set at parameter, message
SYNC. FAILURE n is displayed.
n=1...8 refers to the number of synchronic
axes.
This message is generated in EMG state.
This message causes
EMG state and loss
of reference point. It
can be canceled by
RESET.
91
SYNC. FAILURE 2
92
SYNC. FAILURE 3
93
SYNC. FAILURE 4
94
SYNC. FAILURE 5
95
SYNC. FAILURE 6
96
SYNC. FAILURE 7
97
SYNC. FAILURE 8
100
SHORT 000
If an interface output line is short-
circuited or overloaded, message SHORT
ijk is displayed, where:
i=0 means the 1st, i=1 the 2nd, i=2 the
3rd and i=3 the 4th interface card and j=0
means the first, while j=2 means the sec-
ond 16 output lines on the interface card.
The short-circuited output line is not iden-
tified more exactly, k is always 0.
This message is generated in EMG state.
This message causes
EMG state and loss
of reference point. It
can be canceled by
RESET.
120
SHORT 020
200
SHORT 100
220
SHORT 120
300
SHORT 200
320
SHORT 220
400
SHORT 300
420
SHORT 320