56
Document Number
DCV-00470
Date Released
Jul. 2020
Revision Number/Security level
R03 S2
Retrofit G6-300 + InvencoLink Wayne Vista 3V (US) Installation Guide
Note
:
For a double-sided installation, you will finish with a daisy-
chain of two cables between the pump’s
mains connector and the relay board.
25. Repeat Steps 1 and 3-24 for Side B.
26.
For Side A only
:
a. Connect female end of the EK0127 two-
wire communication cable into the pump’s
communication loom (the connector marked in disassembly Step 11):
Fig. 6.26a
–
Two-Wire Cable connected to Pump Loom
b. Route the EK0127 cable through the bottom of the pump cabinet to the EZ0632 PSU
Plate Assembly that contains the InvencoLink converter, and plug the other end of the
cable into the LINE port on the InvencoLink converter:
Fig. 6.26b
–
Two-Wire Cable connected to InvencoLink
27. Gather all loose wires (on both sides if necessary), neatly wrap them together with cable-ties and
secure to the chassis.
28.
Carefully close each Side pump door, making sure the no cables are pinched, and both the bolts
on each door are properly fastened using the special Wayne Security Key.
EK0127
EK0127
Pump comm. loom