53
Document Number
DCV-00470
Date Released
Jul. 2020
Revision Number/Security level
R03 S2
Retrofit G6-300 + InvencoLink Wayne Vista 3V (US) Installation Guide
19. With the OPT hanging freely, cable tie the bundle of cables to the side of the Insulating Shield
Cover as shown, through the holes provided. Before finally tightening the cable tie, check that
there is enough length of cable to allow the RFK door to be fully opened without placing undue
strain on the cables or the connectors.
Fig 6.19
–
Cable tie cable bundle to Insulating Cover.
20. Route the cable bundle around the corner of the Insulating Cover Shield using cable ties as
shown through the holes provided. Ensure the bend radius and cable ties keep the cable bundle
clear of the sheet metal edges on the corner of the Cover.
Fig. 6.20a
–
Keep cables clear of corner. Fig 6.20b
–
Use cable tie holes provided.
21. The EK0137 AC Mains cable has double-connectors at one end and a single connector at the
other end. Plug the single-connector end into the mains connection on the EZ0632 PSU Plate
assembly.