Press
SET
and the display will show SETUP for standard settings.
The
UP
button is used to increase the setting and for force-running the auger
( hold for longer than 5 seconds ).
The
DOWN
button is used to decrease the setting and switch the controls on/off
( hold for 10 seconds ).
.
Manual
NBE pellet system
USER GUIDE
BOILER TEMPERATURE
Setting the required boiler temperature.
The burner sets the performance higher or lower depending
on the figure entered (set point).
At 10 degrees over this figure the burner will begin to pause or turn itself off.
PAUSE DIFF. TEMP
The setting defining how far the boiler temperature must drop below the desired
value before the burner restarts.
SCREW CAPACITY
After setting the auger performance in 360 seconds the control will
automatically calculate the amount of pellets in low steam and high steam,
pellets in pause , and pellets for ignition
Under normal conditions these numbers will be correct.
To increase combustion, set the value
DOWN
.
To reduce combustion, set the value
UP
.
CHIMNEY DRAUGHT
With a strong chimney draught the ventilator performance will be higher,
At low steam and during pause.
If the amount of chimney draught is increased,
the automatic calculation sets more pellets in low steam and during pause.
The smaller the chimney draught and the greater the back pressure of the boiler,
the lower the value must be.
The greater the chimney draught and the lower the back pressure of the boiler,
the higher the value must be.
YES/NO
Switching automatic calculations on/off.
If automatic calculation is on, only the auger performance can be set.
Current operation
Boiler temperature
Smoke temperature (special apparatus)
Temperature of mechanical stoker
Current performance
Oxygen % (special apparatus)
Current light in combustion head
Various sensor readings
Temperature
Auto combustion
Man. combustion
Timer
Cleaning / power
O2 Control
Temperature
Auto combustion
Man. combustion
Timer
Cleaning / power
O2 Control