EXCEPTION FOR PRESSURE EXPANSION

 

NBE 
Jannich Hansen 
Brinken 10 
DK 9830 Oester Vraa                                                        

 

                                                                                                           

 

Landskronegade 33 

                                                                                                          

2100 Copenhagen 

           Telephone 

39152000 

                                                                                                         

www.arbejdstilsynet.dk

 

 

 

 

 

 

 

 

 

 

 

 

Your contact JH 

                                                                                                           

Our ref. 20030027413 

                                                                                                           

Our contact.      

 

 

 

 

 

 

 

 

 

 

 

 

G.Agersnap  

 

 

 

 

 

 

 

 

 

 

 

Direct telephone 

           0045-3915265915 

 

 

Re: Use of burner to burn wooden pellets type Woody, Scotte, Bio-comfort and  
Boink in boiler equipment in relation to smaller, closed facilities in compliance with Work 
Supervisor Regulations for Hot-water Heating Systems. (publ. 42/1980 para 4)

 

 
With regard to your query of 1 September 2006 concerning the use of the burner to burn wooden 
pellets type Woody, Scotte, Bio-comfort and Boink in boiler equipment in relation to smaller, 
closed facilities with pressure expansion, we can report that the Work Supervisor has perused the 
submitted materials and can declare that the burner for wooden pellets type Woody, Scotte, Bio-
comfort and Boink can be installed in the heat facilities listed in paragraph 4 of the Work Supervi-
sor publication no. 42/1980, Regulations for Hot-water Heating Systems. 
 
It is assumed that the boiler contains the requisite amount of water and that the entire heating fa-
cility is designed in exact compliance with the instructions given in publication 42/1980, and also 
that the electricity supply will only be connected to a boiler with a fitted and connected thermostat 
with the appropriate overheating safety fuse which must be manually reconnected after activation. 
 
All heating in the boiler must take place by means of the pellet combustion chamber, and only 
fuels listed in the instructions may be used. Otherwise the equipment must be installed with an 
open expansion (compare paragraph 2 in publication 42/1980). 
 
This decision is based on the enclosed instructions and diagrams, Test Report no. 300-ELAB-
0741, as well as the Power Dropout Test with readings recording the build-up of heat in the boiler 
if the power supply to the equipment is interrupted. 
 
Best regards, 
 
G.Agersnap 

Summary of Contents for Bio Comfort Series

Page 1: ...100 step modulated Woody Generation EN 303 5 approved by DTI Danish Technological Institute Approved for pressure expansion Energy class AA Wood Pellets Burner Bio comfort...

Page 2: ...850mm Width 700mm 380mm Depth 700mm 560mm Chimney 130mm 130mm Forward flow 1 1 4 1 1 4 Back flow 1 1 4 1 1 4 Lining 1 2 1 2 Efficiency 93 3 89 7 Dragex Draught stabilizer General guidelines The boile...

Page 3: ...tall the auger through the opening over the burner 7 Ensure that the pipe slopes enough to allow the pellets to fall into the burner When using for the first time 8 Make sure there are enough pellets...

Page 4: ...burner and force run the auger until pellets start to come out of it continue for 15 minutes Then weigh the amount of pellets after 360 seconds and enter the result into the controls as the capacity o...

Page 5: ...on Under normal conditions these numbers will be correct To increase combustion set the value DOWN To reduce combustion set the value UP CHIMNEY DRAUGHT With a strong chimney draught the ventilator pe...

Page 6: ...00 in the morning CLOCK The clock correctness depends on the feed from the power station The clock is calibrated every time when you set it and should match after 1 4 settings WARNING The clock does...

Page 7: ...regulation set to ON The burner sets the amount of pellets to suit the required percentage of oxygen Oxygen regulation set to DISPLAY You can read the percentage but the burner does not set the amoun...

Page 8: ...quired temperature I GAIN Shifts performance in relation to the time the pellet burner deviated from the required temperature D GAIN Shifts performance in relation to the temperature trend of the boil...

Page 9: ...sh is black In this case fewer pellets are required at full load Increase the performance of the auger or reduce the pellets high If there is a weak flame on low load 10 30 performance Small flame and...

Page 10: ...lly suitable as the ash does not normally contain carbon particles or tar Combustion heads Remove the ash and any cinders from the grate Remove any remnants of pellets from underneath the grate Wipe t...

Page 11: ...heated 2 Control fuses broken 3 Contrast button not set on controls Reset overheating fuse Change the fuses Check for short circuits Set contrast button Burner ejects HFI relay 1 Ignition faulty 2 Fau...

Page 12: ...Manual NBE Pellets Systems ELECTRICAL WIRING DIAGRAMS...

Page 13: ...t NBE is liable to the purchaser the responsibility of NBE is limited to direct damage i e damage to connected equipment and indirect damage for loss of earn ings operating losses connection costs etc...

Page 14: ...Find the oxygen regulation in the menu and select DISPLAY Switch to the extended menu and calibrate the oxygen and the sensor Note the exhaust gas oxygen sensor must be held in the air The burner wil...

Page 15: ...Manual NBE Pellets Systems MOUNTING THE PELLET HOPPER...

Page 16: ...tte Bio comfort and Boink can be installed in the heat facilities listed in paragraph 4 of the Work Supervi sor publication no 42 1980 Regulations for Hot water Heating Systems It is assumed that the...

Reviews: