14        Maintaining the Boiler

4.5    Maintenance Schedules

Owner maintenance

Daily

 

Ɣ

Check the boiler area is free of 
combustible/flammable materials and 
air contaminants.

 

Ɣ

Check the pressure/temperature 
gauge for signs of higher than normal 
pressure.

Monthly

 

Ɣ

Visually inspect the vent piping for 
signs of leakage and blockage.

 

Ɣ

Visually inspect the burner flames.

 

Ɣ

Inspect the condensate trap and the 
PVC fittings.

Periodically 

 

Ɣ

Test the LWCO for proper operation.

Every 6 months

 

Ɣ

Inspect boiler piping (gas and water) 
for leaks.

 

Ɣ

Test to make sure the relief valve is 
operating normally.

Non-heating 

season

 

Ɣ

Shut boiler down (unless boiler is used 
for domestic hot water).

Service technician (See the following instructions)

Annual Start-up

General:

 

Ɣ

Address reported problems.

 

Ɣ

Inspect interior; clean and vacuum if 
necessary.

 

Ɣ

Clean condensate trap and fill with 
fresh water.

 

Ɣ

Check for leaks (water, gas, flue, 
condensate).

 

Ɣ

Verify flue and air lines in good 
condition and sealed tight.

 

Ɣ

Check system water pressure/system 
piping/expansion tank.

 

Ɣ

Check control settings.

 

Ɣ

Check ignition and flame rod (clean and 
reposition).

 

Ɣ

Check wiring and connections.

 

Ɣ

Inspect flame (stable, uniform).

 

Ɣ

Inspect flame signal.

If combustion or performance indicate 
need:

 

Ɣ

Flush heat exchanger.

 

Ɣ

Remove and clean air intake filter.

4.4    Protecting the Boiler from Freezing

CAUTION

Damage due to freezing is not covered by the Navien limited 
warranty.

 

Ɣ

Freezing damage is most likely to occur due to back drafting 
caused by negative pressure in the building. This is not a 
manufacturing defect, and therefore, Navien will not warrant 
any damages due to freezing. The installer is responsible for 
ensuring that there is sufficient make-up air to avoid such 
a situation and the owner is responsible for ensuring that 
protection against freezing is maintained.

 

Ɣ

To avoid freezing issues, we strongly recommend the use of 
a direct vent exhaust and intake system. Your installer should 
ensure that the exhaust vent pipe and the air intake pipe are 
both connected directly from the collars on the top of the 
boiler to the outdoors. This type of vent system minimizes 
air movement within the boiler.

 

Ɣ

This boiler has an optional recirculation mode that is used for 
freeze protection. This mode should prevent the boiler from 
freezing, even if the intake air duct is not vented directly.

 

Ɣ

The boiler is designed for indoor installation only.

To ensure that the boiler does not freeze, follow these guidelines:

 

Ɣ

Do not unplug the power supply cord,

 except for routine 

maintenance. The boiler has a freeze protection function that 
requires electricity. The freeze protection function will operate 
regardless of whether or not the power is turned on or off, as 
long as the electric supply is still connected.

 

Ɣ

Do not close the gas valve,

 except for routine maintenance, as 

this will limit additional freeze protection.

 

Ɣ

If the boiler will not be used for an extended period, drain 
the boiler.

If the power or gas supplies must be disconnected for an 
extended period, drain the boiler. Freezing damage may occur if 
there is water remained in the boiler in cold weather.

Note

 

Ɣ

If hot water will not flow and you suspect that the 
boiler is frozen, contact an authorized technician or 
licensed professional.

 

Ɣ

This boiler requires very little maintenance, however 
a qualified technician should inspect the boiler at 
the beginning of every heating season and/or when 
there is a problem.

Summary of Contents for NHB-110

Page 1: ...nce Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your...

Page 2: ...oiler On or Off 8 3 2 Adjusting the Temperature 8 3 3 Viewing Basic Information 9 3 4 Resetting the Boiler 10 4 Maintaining the Boiler 11 4 1 Cleaning the Boiler 11 4 2 Draining the Boiler 11 4 3 Clea...

Page 3: ...pplier call the fire department Do not return to your home until authorized by your gas supplier or the fire department C Do not use this appliance if any part has been under water Immediately call a...

Page 4: ...shut off turn off the manual gas valve to the appliance WARNING Shut off the gas supply if the boiler is damaged Have your installer or plumber show you the location of the gas shut off valve and dem...

Page 5: ...e temperature and if necessary initiates a safety heating cycle to prevent internal equipment damage due to freezing temperatures Short Circuit Protection Any short circuit occurring in the boiler s e...

Page 6: ...peration Refer to the following table for detailed information a Space heating mode f S Supply water control Indicates space heating mode operation Indicates supply water control status b Error g R Re...

Page 7: ...ler s operation such as space heating and DHW supply temperatures Refer to the following table for detailed information k Diagnostics button n Up button For installers only Increases the temperature l...

Page 8: ...fault space heating return water temperature range is 86 F 30 C Absolute MIN to 149 F 65 C Absolute MAX You can adjust the temperature range in the parameter settings menu The boiler will retain your...

Page 9: ...Low mass radiant 5 High mass radiant 6 Radiator 7 Custom set by installer 3 2 2 Adjusting the DHW Indirect Supply Temperature To adjust the water temperature 1 Press the Mode button twice The DHW mod...

Page 10: ...ooting section of this manual or contact Technical Support at 1 800 519 8794 Display Description psi O R S R Pri Boost interval time set by installer psi O R S R Pri Space heating water pressure in PS...

Page 11: ...e resistant but it is not waterproof Keep it as dry as possible 4 2 Draining the Boiler You will need to drain the boiler before performing maintenance tasks such as to prevent the boiler from freezin...

Page 12: ...clean the air intake filter every 3 4 months To clean the air intake filter 1 Press the Power button on the front panel to turn off the boiler MODE 2 Disconnect the power supply to the boiler 3 Remov...

Page 13: ...of the boiler 6 Remove the filter from the plastic assembly Dust and rinse it with clean running water 7 Allow the filter to dry completely 8 Place the filter assembly back into the boiler and secure...

Page 14: ...freezing The installer is responsible for ensuring that there is sufficient make up air to avoid such a situation and the owner is responsible for ensuring that protection against freezing is maintain...

Page 15: ...e service and maintenance could result in damage to the boiler or system Failure to follow the directions in this manual and component literature could result in severe personal injury death or substa...

Page 16: ...ts over time rendering the valve inoperative Such conditions are not detectable unless the valve and its components are physically removed and inspected This inspection must only be conducted by a plu...

Page 17: ...r is clean Review with the Owner 1 Review the User s Information Manual with the owner 2 Emphasize the need to perform the maintenance schedule 3 Remind the owner of the need to call a licensed contra...

Page 18: ...inutes d Close the B valve and open the D valve 11 Disconnect all tubes and valves 12 Reconnect the power supply to the boiler 13 Press the Power button on the front panel to turn on the boiler To flu...

Page 19: ...the system in stand by Make sure the power is on and plugged into the outlet with the correct voltage Press the Power button and raise the setting temperature Make sure the boiler is turned on Is the...

Page 20: ...On reset E205 Abnormal operation heating supply thermistor Auto reset E218 Abnormal operation heating return thermistor Alarm E271 Temperature differential limit Alarm E278 Abnormal operation system...

Page 21: ...uct If the original installer cannot be identified the end user or homeowner may contact Navien s Technical Administration Department at 800 519 8794 Proof of purchase is required to obtain warranty s...

Page 22: ...F NAVIEN HAD OR SHOULD HAVE HAD ANY KNOWLEDGE ACTUAL OR CONSTRUCTIVE OF THE POSSIBILITY OF SUCH DAMAGES Warranty Exclusions Navien s Limited Warranty shall be void in the event of an occurrence of any...

Page 23: ...Memo...

Page 24: ...er Contact a licensed professional for the affected system for example a plumber or electrician When you contact Technical Support please have the following information at hand Model number Serial num...

Reviews: