background image

22        Warranty

 

Ɣ

Improper conversion from natural gas to LP gas or LP gas 
to natural gas or attempt to operate with a type of gas not 
specified for the boiler.

 

Ɣ

Any damage, malfunction or failure caused by abuse, 
negligence, alteration, accident, fire, flood, freezing, wind, 
lightning and other acts of God.

 

Ɣ

Operating, using or storing the boiler in a corrosive or 
contaminated atmosphere or environment.

 

Ɣ

Operating the boiler at water temperatures outside the factory 
calibrated temperature limits and/or exceeding the maximum 
setting of the high limit control.

 

Ɣ

Operating the boiler when it is not supplied with potable water 
at all times.

 

Ɣ

Subjecting the heat exchanger to pressures or firing rates 
greater or lesser than those shown on the rating plate.

 

Ɣ

Installation at any location outside the United States and 
Canada.

 

Ɣ

Removal or alteration of the rating plate.

Other Terms

: This Limited Warranty is subject further to the terms 

and conditions set forth herein and as may be further specified 
in the terms and conditions page located on Navien’s website 
at www.navien.com. WITH THE EXCEPTION OF THIS LIMITED 
WARRANTY, NAVIEN DISCLAIMS ANY OBLIGATION OR LIABILITY 
WITH RESPECT TO THE PRODUCTS OR THEIR SALE AND USE, AND 
NAVIEN NEITHER ASSUMES NOR AUTHORIZES THE ASSUMPTION 
OF, ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THE 
PRODUCTS. THIS DISCLAIMER INCLUDES ANY OTHER WARRANTIES, 
EXPRESS, IMPLIED OR STATUTORY RESPECTING THE PRODUCTS 
OR ANY PARTS OR COMPONENTS THEREOF, INCLUDING, BUT NOT 
LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY 
OR FITNESS FOR A PARTICULAR PURPOSE. Navien’s total liability 
for any claim arising hereunder shall not exceed the purchase 
price which you paid for the product. NAVIEN SHALL NOT IN ANY 
EVENT BE LIABLE FOR INDIRECT, SPECIAL, CONSEQUENTIAL OR 
LIQUIDATED DAMAGES OR PENALTIES, INCLUDING CLAIMS FOR 
LOST REVENUE, PROFITS OR BUSINESS OPPORTUNITIES, EVEN IF 
NAVIEN HAD OR SHOULD HAVE HAD ANY KNOWLEDGE, ACTUAL 
OR CONSTRUCTIVE, OF THE POSSIBILITY OF SUCH DAMAGES. 

Warranty Exclusions

Navien’s Limited Warranty shall be void in the event of an 
occurrence of any of the following:

 

Ɣ

Improper installation, failure to install in strict compliance with 
the Installation & Operation Manual procedures, installed by a 
non-licensed installer, and installation in violation of applicable 
rules, laws or building codes.

 

Ɣ

Product purchased through the internet, other e-commerce 
channels, or any installer that obtained the product from a 
supplier or distributor not authorized by Navien. 

 

Ɣ

Failure to perform regular maintenance, misuse, operation at 
settings other than those recommended or specified, non-
compliance with instructions or guidelines set forth in the User’s 
Information Manual.

 

Ɣ

Modification or alteration of the product in any manner, 
including but not limited to, removal of any component or 
part, addition of any non-approved components, relocating 
or moving the product from its original installation site, or any 
accidental or intentional damage to the Product.

 

Ɣ

Installation for non-recommended uses.

 

Ɣ

Any damage caused by local adverse conditions including but 
not limited to hard water deposits, lime or mineral build-up, 
operating in corrosive atmospheric elements.

 

Ɣ

Damage or problems caused by gas flow issues, electrical surges, 
flooding, fire, abnormal external temperature, and any other 
cause of damage not directly caused by a manufacturing defect.

 

Ɣ

Installer’s failure to fully comply with the warranty service and 
return policy procedures previously provided to installer and 
as is available on Navien’s website. Such policies include but 
are not limited to the installer’s failure to first contact Navien 
Technical Support while in front of the product for purposes of 
trouble shooting the identified problem or issue.

 

Ɣ

Performance problems caused by improper sizing of the boiler, 
the gas supply line, the venting connection, combustion air 
openings, electric service voltage, wiring, fusing or any other 
components, parts or specifications.

Summary of Contents for NHB-110

Page 1: ...nce Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your...

Page 2: ...oiler On or Off 8 3 2 Adjusting the Temperature 8 3 3 Viewing Basic Information 9 3 4 Resetting the Boiler 10 4 Maintaining the Boiler 11 4 1 Cleaning the Boiler 11 4 2 Draining the Boiler 11 4 3 Clea...

Page 3: ...pplier call the fire department Do not return to your home until authorized by your gas supplier or the fire department C Do not use this appliance if any part has been under water Immediately call a...

Page 4: ...shut off turn off the manual gas valve to the appliance WARNING Shut off the gas supply if the boiler is damaged Have your installer or plumber show you the location of the gas shut off valve and dem...

Page 5: ...e temperature and if necessary initiates a safety heating cycle to prevent internal equipment damage due to freezing temperatures Short Circuit Protection Any short circuit occurring in the boiler s e...

Page 6: ...peration Refer to the following table for detailed information a Space heating mode f S Supply water control Indicates space heating mode operation Indicates supply water control status b Error g R Re...

Page 7: ...ler s operation such as space heating and DHW supply temperatures Refer to the following table for detailed information k Diagnostics button n Up button For installers only Increases the temperature l...

Page 8: ...fault space heating return water temperature range is 86 F 30 C Absolute MIN to 149 F 65 C Absolute MAX You can adjust the temperature range in the parameter settings menu The boiler will retain your...

Page 9: ...Low mass radiant 5 High mass radiant 6 Radiator 7 Custom set by installer 3 2 2 Adjusting the DHW Indirect Supply Temperature To adjust the water temperature 1 Press the Mode button twice The DHW mod...

Page 10: ...ooting section of this manual or contact Technical Support at 1 800 519 8794 Display Description psi O R S R Pri Boost interval time set by installer psi O R S R Pri Space heating water pressure in PS...

Page 11: ...e resistant but it is not waterproof Keep it as dry as possible 4 2 Draining the Boiler You will need to drain the boiler before performing maintenance tasks such as to prevent the boiler from freezin...

Page 12: ...clean the air intake filter every 3 4 months To clean the air intake filter 1 Press the Power button on the front panel to turn off the boiler MODE 2 Disconnect the power supply to the boiler 3 Remov...

Page 13: ...of the boiler 6 Remove the filter from the plastic assembly Dust and rinse it with clean running water 7 Allow the filter to dry completely 8 Place the filter assembly back into the boiler and secure...

Page 14: ...freezing The installer is responsible for ensuring that there is sufficient make up air to avoid such a situation and the owner is responsible for ensuring that protection against freezing is maintain...

Page 15: ...e service and maintenance could result in damage to the boiler or system Failure to follow the directions in this manual and component literature could result in severe personal injury death or substa...

Page 16: ...ts over time rendering the valve inoperative Such conditions are not detectable unless the valve and its components are physically removed and inspected This inspection must only be conducted by a plu...

Page 17: ...r is clean Review with the Owner 1 Review the User s Information Manual with the owner 2 Emphasize the need to perform the maintenance schedule 3 Remind the owner of the need to call a licensed contra...

Page 18: ...inutes d Close the B valve and open the D valve 11 Disconnect all tubes and valves 12 Reconnect the power supply to the boiler 13 Press the Power button on the front panel to turn on the boiler To flu...

Page 19: ...the system in stand by Make sure the power is on and plugged into the outlet with the correct voltage Press the Power button and raise the setting temperature Make sure the boiler is turned on Is the...

Page 20: ...On reset E205 Abnormal operation heating supply thermistor Auto reset E218 Abnormal operation heating return thermistor Alarm E271 Temperature differential limit Alarm E278 Abnormal operation system...

Page 21: ...uct If the original installer cannot be identified the end user or homeowner may contact Navien s Technical Administration Department at 800 519 8794 Proof of purchase is required to obtain warranty s...

Page 22: ...F NAVIEN HAD OR SHOULD HAVE HAD ANY KNOWLEDGE ACTUAL OR CONSTRUCTIVE OF THE POSSIBILITY OF SUCH DAMAGES Warranty Exclusions Navien s Limited Warranty shall be void in the event of an occurrence of any...

Page 23: ...Memo...

Page 24: ...er Contact a licensed professional for the affected system for example a plumber or electrician When you contact Technical Support please have the following information at hand Model number Serial num...

Reviews: