Cleaning the boiler
24
If the oil filter is dirty, stop operation of the boiler, close the oil valve, and remove dust and
rust below the oil filter cup.
1. Turn off the boiler.
2. Separate the oil filter cup connected to the flexible hose nearby the inlet of the
gear pump, by turning the cup counter-clockwise.
3. Separate the strainer screen by pulling it out downward.
4. Clean the strainer screen and inside the oil filter cup using the clean boiler oil or
the light oil.
Cleaning the oil filter
Ȅ
Do not forget to wear gloves while cleaning.
<Figure 2>
<Figure 3>
<Figure 1>
Dirt and fume deposits on the photoelectric tube causes deteriorated sensitivity of the tube,
and the photoelectric tube may fail to detect the flame, which eventually leads to failure of
combustion.
1. Pull out the flame detector (Black) attached to below the burner.
2. Wipe the glass surface of the flame detector with clean cloth.
3. Fit the flame detector into the burner until you hear a snap sound, after cleaning.
Cleaning the flame detector
ූ
Be sure to turn the power on, while cleaning the flame detector.
ූ
Never wipe the flame detector with wet cloth or oil.
ූ
Do not pull the wire out while separating the flame detector.
<Figure 1>
<Figure 2>
Summary of Contents for LST-58K
Page 1: ...LST 58K...
Page 2: ......
Page 11: ...The structure and its description 11 Boiler LST 58K...
Page 28: ...Outside drawing on the boiler 29 LST 58K...
Page 42: ...43 Standard piping drawing Open expansion Combi boiler Closed expansion Combi boiler...
Page 51: ...55 Electric wiring diagram IU08 2 IU0 D 2 OFU05G IU08K DU06P...
Page 53: ...memo 57...
Page 54: ...58 memo...
Page 55: ......