blinks when selecting
Room Temp. Mode
When blinks, set the desired
heating temp. between 10~40
丯
by
adj/- button, after a while,
it is automatically saved.
Heating temp. can be set by 1
丯
.
After the setting is done,
is on and current room temp.
is displayed.
If a room thermostat is programmed with Room Temp. Mode
and it is placed in the following places when using Room Temp.
mode, it may cause some errors to recognize temperature.
1. Frequently opened and closed door and drafty place.
2. A place where direct sunlight is effected and high humidity.
3. A place under direct influence from heat, such as radiator.
In that case, Heating Water Temp. is recommended.
Press the Mode button repeatedly,
until is displayed.
S
et the heating temp.
with +/- button.
CAU
T
ION
Room
T
em
p
. Mo
d
e
16