54
Maintenance
Yearly appliance check and maintenance
The followings checks and maintenance activity should be performed
at least one time per year :
Cleaning of the burner
V
isual inspection of the exhaust duct for wear or corrosion checking
Correct ignition and detection
Correct burner setting in heating and domestic hot water production
Correct operation of the main switch upstream the boiler
Correct operation and adjustment of the boiler regarding :
- Activation of the heating control system
- Activation of the domestic hot water production system
Checking of the correct activation of the detection control system;
its activation must be shorter than 10 seconds.
Watertight of the boiler heating and domestic hot water production circuit;
no leakage or water oxidation have to appear around the coupling.
V
isual Checking that the outlet of the pressure relief valve is not blocked.
V
isual checking that the safety and control devices have not been tampered
or short- circuited; in particular:
- Temperature safety limit thermostat
V
isual checking of the electrical system; in particular:
- Electrical power cable must be no damaged and properly blocked.
- No trace of blackening or burning must be exist anywhere.
Summary of Contents for LST-58K
Page 1: ...LST 58K...
Page 2: ......
Page 11: ...The structure and its description 11 Boiler LST 58K...
Page 28: ...Outside drawing on the boiler 29 LST 58K...
Page 42: ...43 Standard piping drawing Open expansion Combi boiler Closed expansion Combi boiler...
Page 51: ...55 Electric wiring diagram IU08 2 IU0 D 2 OFU05G IU08K DU06P...
Page 53: ...memo 57...
Page 54: ...58 memo...
Page 55: ......