Check
p
oint for test o
p
eration
52
1
) Check if the boiler is installed correctly.
Η
Check if the floor surface is made of strong, flat, and non-flammable materials
such as concrete and if the surrounding area is also made of non-flammable
materials.
Θ
Check the air intake and the vent in the boiler room.
Ι
Check if the boiler room is provided with a drain, and if the boiler is equipped
with the drain valve.
Κ
Check if the boiler and the pipeline are heat insulated to prevent frost damage.
Λ
Check if the chimney pipe is correctly installed
Μ
Check if rain does not permeating through the penetration portion of the exhaust
pipe.
Ν
Check if the boiler is evenly installed.
Ξ
Check if there is water leakage near the piping connection joint.
Ο
Check if there is any leakage near the oil pipe connection joint.
Π
Check if the pressure release pipe or the safety valve are installed in the boiler.
Ρ
Check if the ground wire is connected. (If the ground connection is made on the
fuel pipe or the lightning rod, change the position.)
Check if the fuel is the same as the oil specified on the name plate of the boiler.
Σ
The oil tank shall be installed in a place free from the impact of fire, rain, and dust,
and without the direct sunlight. Check if there is a partition wall between the place
of the oil tank and the boiler room.
Summary of Contents for LST-58K
Page 1: ...LST 58K...
Page 2: ......
Page 11: ...The structure and its description 11 Boiler LST 58K...
Page 28: ...Outside drawing on the boiler 29 LST 58K...
Page 42: ...43 Standard piping drawing Open expansion Combi boiler Closed expansion Combi boiler...
Page 51: ...55 Electric wiring diagram IU08 2 IU0 D 2 OFU05G IU08K DU06P...
Page 53: ...memo 57...
Page 54: ...58 memo...
Page 55: ......