Mechanical Procedures
Step 5:
Install the Console to the Mast using the four Phil-
lips screws that you removed in Step 1. See
Figure
1a
and
1b
.
REMOVING THE MAST:
Tools needed:
Phillips screwdriver or Cordless drill with Phillips tip
6 mm Allen wrench
8 mm Allen wrench
Step 1:
Remove the console according to the REMOVING
THE CONSOLE procedure.
Step 2:
For the U916 only – Remove the Upright Handlebar
according to REMOVING THE UPPER HANDLE BAR
procedure.
Step 3:
Remove the right and left Mast covers with a phil-
lips screw driver. See
Figure 3a
and
3b
.
Step 4:
For the U916 only – Remove the Cupholder from the
Mast with a phillips screwdriver (see
Figure 4
).
Step 5:
Using a 8mm Allen wrench, remove the four bolts
securing the Mast to the bottom half frame. See
Figure 5a
and
5b
.
figure 3a - Remove right mast cover
figure 3b - Remove left mast cover
figure 4 - Remove cupholder (U916 only)
figure 5a - Unbolt mast from frame (U916)