Refer.to.the.following.table.to.scan.through.and.customize.the.settings:
Table 2–3. Machine Status
Step No. Press Keys
Display (What you will see)
1
▲
, 4, ENTER
MACHINE STATUS
2
▼
or
▲
MAINT HOURS,
U/R916
[or other], CONS,
DISTANCE, WORKOUTS, RUN HOURS
3
clEaR
SELECT WORKOUT
Maint Hours
.–.displays.the.number.of.hours.(incremented.every.hour).the.machine.has.been.running...The.start.value.is.set.
under.the.Maintenance.Logs.service.screen..(The.start.value.can.be.set.to.any.value—e.g..if.the.service.tech.had.entered.
100.in.the.Maintenance.Logs.service.screen.and.there.was.1.hour.of.running.time.on.the.machine,.the.value.under.this.
Maint.Hours.screen.would.read.101).
Machine Type
.–.should.display.U/R916..“NTM.Config.REQD”.appears.on.the.console.if.the.software.has.been.updated.on.
the.machine.or.the.machine.froze.up.and.the.power.had.to.be.cycled..The.message.also.appears.when.the.console.assembly.
has.been.replaced.and.no.configuration.established..Configuring.the.machine.will.eliminate.this.message.(see.the.table.
“Machine.Configuration”).
Distance
.–.displays.the.total.distance.in.miles.(or.kilometers).of.machine.operation...This.value.is.auto-incremented.every.
1/100th.or.1/10th.unit,.depending.on.how.many.miles/km.have.accrued.
Workouts
.–.displays.the.total.number.of.workouts.performed.on.the.machine...This.value.is.auto-incremented.only.if.the.
user.enters.a.workout.and.either.completes.the.workout.or.presses.the.[STOP].key.twice.
Run Hours
.–.displays.the.total.number.of.hours.on.the.machine.
noTE:
..The.R&D.options.(codes.starting.with.5).are.not.used.for.servicing.machines..Do.not.change.these.settings..If.an.
R&D.setting.is.inadvertently.changed,.it.will.reset.when.the.machine.is.powered.off.and.then.back.on.
Diagnostics
Use.diagnostic.codes.to.test.various.components.of.the.machine.such.as.the:
•. tachometer.
•. alternator
•. I/O
•. sensor.(for.EV9.16.only)
•. serial.ports
•. keypad.
•. display
Diagnostics