MoniMax 7600T
Installation Manual
33
3.
Check the status of CDU Rail Guide bracket.
Normally all fixing screws should be located at the proper position, as shown in the picture
1) Open the safe door and upper door
2) Remove the affixing screws on the cash dispenser rail (left picture) and upper one.
(right picture)
3) Make sure that all connectors like communication cables, power cables and data cables inside
modules which is connected to cash dispenser, card reader, receipt printer, envelope depository,
control electronics and so on are completely connected or not.
4) Mount the supplementary parts into the each module such as cash cassette, receipt paper,
journal paper, ribbon cassette, envelope box, inkjet printer head and so on.
Note : Concerning how to mount or replenish these above, please refer to the MoniMax 7600T
operator manual