Issue 1.1
Main Menu
Select
Back
12:43:16 Power: 0W Side A Bypass
Factory Settings
Calibrate Meters
Set Thresholds
Maximum Output Gain
Use Factory Settings
Main Menu
Select
Back
12:43:16 Power: 0W Side A Bypass
12:43:16 Power: 0W Side A Bypass
Factory Settings
Calibrate Meters
Set Thresholds
Maximum Output Gain
Use Factory Settings
(a) From the main menu, highlight
Settings
(using
f
and
g
) and press
Select
.
Highlight
Timed Shutdown
and press
Select
.
(b) Use
f
and
g
to highlight
Timed
Shutdown
,
Interval
or
Auto Assert
,
noting:
x
For
Timed Shutdown
, press
Toggle
to
change between
ENABLED
and
DISABLED
. When
Timed Shutdown
is
ENABLED
, the transmitter will shut down
the
Interval
period (in hours:minutes)
after
RF On
is asserted.
x
For
Interval
, press
Modify
to enable
editing of the interval time. Use
f
and
g
to change the interval between 5 minutes
and 24 hours (in 5 minute increments).
Press
Done
to store the change.
x
For
Auto Assert
, press
Modify
to enable
editing of the asserting monitor point. Use
f
and
g
to change the monitor point
between 1 and 40 (or Disabled). Press
Done
to store the change. Monitor points
can only enable the timed shutdown
timer. Set
Timed Shutdown
to
DISABLED
when using
Auto Assert
.
3.6.12 Changing Factory Calibrated
Settings
Certain parameters, calibrated during factory
testing, can be changed, in local control only,
if an out-of-tolerance condition occurs.
(a) From the main menu, highlight
Settings
(using
f
and
g
) and press
Select
.
Highlight
Factory Settings
and press the
f
and left soft-key simultaneously.
Press
Yes
to display the following options:
(b) Press
f
or
g
to scroll through the
options and press
Select
to enter the
appropriate sub-menu (see appropriate
paragraph 3.6.12.1 through 3.6.12.4):
Warning: Modifying these
settings can affect your
transmitter operation.
Do you wish to continue?
Yes
No
12:43:16 Power: 0W Side A Bypass
Warning: Modifying these
settings can affect your
transmitter operation.
Do you wish to continue?
Yes
No
12:43:16 Power: 0W Side A Bypass
12:43:16 Power: 0W Side A Bypass
Select
Meters
12:43:16 Power: 0W Side A Bypass
Main Menu
Changeover Control
Events Log
Settings
Peripherals
RCMS Settings
Vector NDB HP
rev 1. 0. 1. 2
Apr 24 2007
15:17:38
Nautel
Select
Meters
12:43:16 Power: 0W Side A Bypass
12:43:16 Power: 0W Side A Bypass
Main Menu
Changeover Control
Events Log
Settings
Peripherals
RCMS Settings
Vector NDB HP
rev 1. 0. 1. 2
Apr 24 2007
15:17:38
Nautel
Settings
Monitor Settings
Meter Settings
Power Source Select
Configure Sonalert
Factory Settings
Main Menu
Select
Back
12:43:16 Power: 0W Side A Bypass
Settings
Monitor Settings
Meter Settings
Power Source Select
Configure Sonalert
Factory Settings
Main Menu
Select
Back
12:43:16 Power: 0W Side A Bypass
12:43:16 Power: 0W Side A Bypass
Main Menu
Toggle
Back
12:43:16 Power: 0W Side A Bypass
Timed Shutdown
Timed Shutdown
[DISABLED ]
Interval
[00:05 ]
Auto Assert
[Monitor Point 1 ]
Timer State:
Stopped 00:05:00
Main Menu
Toggle
Back
12:43:16 Power: 0W Side A Bypass
12:43:16 Power: 0W Side A Bypass
Timed Shutdown
Timed Shutdown
[DISABLED ]
Interval
[00:05 ]
Auto Assert
[Monitor Point 1 ]
Timer State: