![Nautel NV30LT-N Operation & Maintenance Manual Download Page 81](http://html1.mh-extra.com/html/nautel/nv30lt-n/nv30lt-n_operation-and-maintenance-manual_3545794081.webp)
NV30LT-N OPERATIONS & MAINTENANCE MANUAL
OPERATING THE TRANSMITTER
VERSION 0.1 2015-03-01
PAGE 3.2.63
Other Settings - (see
)
:
Other Settings:
Provides the following sub-functionality:
Pilot Level: enter value between 6 and 12 % (typically 9 %). This level is added to the
composite baseband signal.
Pilot 1 PPS Sync: select Enabled or Disabled.
Pilot Sync Phase: if Pilot 1 PPS Sync is enabled, enter value between 0 and 360 degrees
(typically 0 degrees).
NOTE
:
The Pilot Level, Pilot 1 PPS and Pilot Sync Phase settings are displayed for all Audio Source
selections, but will have no effect on presets with MPX or MPX Over AES sources.
Sample Output: determines which sample signal will be present on exciter’s rear panel
PILOT/
MPX SAMPLE OUT
BNC connector. Select Pilot (default setting, pilot sample present) or MPX
(Composite) (composite baseband signal present).
Audio Delay: select Enabled, then enter value in the allowable range of 0 to 12000 ms. Default
is 0. Audio Delay is used to time align the receiver output of decoded analog and digital audio
signals.
Mod Loss Timeout: select Enable if so required. If Enable is selected the following sub-fields
will appear:
–
Action
: select the action to take on the loss of a modulating signal post the timeout period. Select
None
(no resulting action),
Inhibit
(inhibits the RF output and fans until the audio returns) or
Change Preset
(changes the active preset).
–
Mod Loss Preset
: displayed only if
Action
is set to
Change Preset.
Select the preset from the drop
down list that will activate upon the loss of a modulating signal, post the timeout period.
–
Timeout Minutes
: sets the delay, in minutes, between modulation loss detection and the resulting
action. Enter a value in the allowable range of 0 and 255 minutes.
–
Timeout Seconds
: sets the delay, in seconds, between modulation loss detection and the resulting
action. Enter a value in the allowable range of 0 and 59.9 seconds.
–
Threshold
: sets the threshold for modulation loss detection. Enter a value in the allowable range of 0 and
100%.
(see
Configuring a Mod Loss Backup Preset on page 3.4.4
Hard Limiter: select Enabled, then enter the hard limit threshold percentage (allowable range
is 0-160%, defaulted to 140%). If enabled, the modulation level will be limited (audio signal
clipped or distorted) if it exceeds the hard limit threshold.
Summary of Contents for NV30LT-N
Page 2: ......
Page 4: ......
Page 8: ...NV30LT N OPERATIONS MAINTENANCE MANUAL PAGE 3 VIII VERSION 0 1 2015 03 01...
Page 18: ...NV30LT N OPERATIONS MAINTENANCE MANUAL DESCRIPTION PAGE 3 1 10 VERSION 0 1 2015 03 01...
Page 224: ...NV30LT N OPERATIONS MAINTENANCE MANUAL LIST OF TERMS PAGE 3 5 2 VERSION 0 1 2015 03 01...
Page 225: ......