![Nautel NV30LT-N Operation & Maintenance Manual Download Page 176](http://html1.mh-extra.com/html/nautel/nv30lt-n/nv30lt-n_operation-and-maintenance-manual_3545794176.webp)
NV30LT-N OPERATIONS & MAINTENANCE MANUAL
OPERATING THE TRANSMITTER
PAGE 3.2.158
VERSION 0.1 2015-03-01
In the
Input
section, use the drop-down menu to select the desired input (alarm, status or
custom input) that will affect the rule. Note that a second input may also be selected in
conjunction with a logic operation if the
Operator
section contains the AND, OR or XOR
function.
In the
Logic
section, use the drop-down menu to select “
Is True
” or “
Is False
” to indicate the
trigger for the assertion of the rule. Select “
Is True
” when you want the rule to assert when
the associated input is active. Select “
Is False
” when you want the rule to assert when the
associated input is inactive.
In the
Operator
section, use the drop-down menu to select a logic operation to combine two
inputs. Select “blank” for no logic operation (i.e., for single input rules). For rules that use two
inputs, select
AND
,
OR
or
XOR
, noting:
– the AND function requires both inputs to be asserted (according to their selected Logic states) to activate the
rule.
– the OR function requires one or both inputs to be asserted (according to their selected Logic states) to
activate the rule.
– the XOR function requires one - and only one - input to be asserted (according to their selected Logic states)
to activate the rule.
Press the
Apply
button to save the rule or the
Cancel
button to return to the
Site Control
page.
The
Site Control
page will display all rules, with the user-defined characteristics described above.
Additionally, the current
State
of the rule will be displayed in a check-box on the right-hand side of the
page. A checked box indicates the rule is currently active.
Applying a Site Control Rule to a Remote Input/Output
You can apply a site control rule as a
Remote Output
by selecting the desired rule from the
Channel
list in either the
Remote Outputs
tab. The
Channel
list should contain the names of all existing rules.
Remote I/O Settings - Using the AUI, on page 3.2.145
for more details on configuring remote inputs
and outputs.
Custom remote inputs can be created in the
Remote Inputs
tab. These inputs can be used within a site
control rule.
Summary of Contents for NV30LT-N
Page 2: ......
Page 4: ......
Page 8: ...NV30LT N OPERATIONS MAINTENANCE MANUAL PAGE 3 VIII VERSION 0 1 2015 03 01...
Page 18: ...NV30LT N OPERATIONS MAINTENANCE MANUAL DESCRIPTION PAGE 3 1 10 VERSION 0 1 2015 03 01...
Page 224: ...NV30LT N OPERATIONS MAINTENANCE MANUAL LIST OF TERMS PAGE 3 5 2 VERSION 0 1 2015 03 01...
Page 225: ......