17
Installation and Maintenance Manual
17. FLOW COMPENSATOR ADJUSTMENT ( FOR REMOTE CHILLER MODEL ONLY )
18. WATER LEAK PROTECTION DEVICE ADJUSTMENT
WATER INLET FROM MAIN
WATER SOURCE.
EXTERNAL RESET TRIGGER
PUSH TO RESET.
WATER OUTLET TO WATER
SHUTOFF VALVE.
WATER LEAK PROTECTION
DEVICE MUST BE INSTALLED
IN THE VERTICAL POSITION
FOR PROPER OPERATION.
SET TO 1,2 OR 3.
DO NOT EXCEED 3
WATER LEAK PROTECTION
ADJUSTMENT KEY.
The
CO
2
water
fl
ow has been factory-set to provide
the proper
fl
ow rate of approximately 1liter/15 sec.
However, it may be necessary to adjust this in the
fi
eld.
To adjust the
fl
ow, insert a 6mm Allen wrench into
the adjustment screw of the Compensator Valve.
Turning clockwise, the
fl
ow rate will decrease.
Turning counter-clockwise the
fl
ow rate will increase.
It is recommended to adjust the valve approximately
½ turn each time. A proper setting is important for
correct carbonation level.
WATER INLET FROM
REMOTE CHILLER
VALVE ADJUSTMENT
PLASTIC SCREW
6MM ALLEN WRENCH
WATER OUTLET TO
CARBONATED
WATER TAP
MOUNTING
BRACKET
IMPORTANT:
PROPER INSTALLATION OF THE
WATER LEAK PROTECTION DEVICE
IS REQUIRED OR WARRANTY WILL
BE VOIDED.
IF NOT INSTALLED PROPERLY
CONSUMER WILL BE RESPOSIBLE
FOR ANY DAMAGES.