background image

18

Installation and Maintenance Manual

The Water Leak Protection Device is an over

fl

 ow safety device that controls the maximum 

consumption of water between 5 and 50 liters.  

Its function is to measure the volume of water that passes through it.  If this volume exceeds 

the set value, the Water Leak Protection Device stops the 

fl

 ow and stays in the safety 

condition until user intervention.  

1. 

The device should be installed in a vertical orientation directly to the outlet port of the  

 Braided 

Hose

  

2. 

All connections are the “face seal” type, and should not be over tightened.

3. 

The device is equipped with a valve adjustment.

4. 

To adjust the device, separate the two black plastic housings.  

5. 

The adjustment location is on the external threaded end of the main housing.

6. 

Insert the key provided into the adjustment slot .

7. 

Turn the key until the valve is set at 1, 2, or 3.  Do not exceed 3. This setting controls the  

 

amount of water that is permitted to 

fl

 ow before the device trips and stops the water  

 

fl

 ow.

8. 

Reassemble the two black plastic housings.

Water Leak Protection Device Reset

The Water Leak Protection Device is supplied with a Reset Adapter.  This allows you to reset 

the device if it has nuisance cycled. For example, 

fi

 lling a stock pot (more than 3 gallons) 

without a pause.  

To reset, simply push the red Reset Trigger. Due to line pressure, it may require some force to 

depress the red Reset Trigger.

Summary of Contents for NWSBU2 SER.4

Page 1: ...MAINTENANCE GUIDE FOR NATURA Water LLC 222 East Campus View Blvd Columbus Ohio 43235 U S A NATURA MODEL NWSB SER 4 COUNTERTOP WATER DISPENSER Aquarius Series NATURA MODEL NWSBU2 SER 4 REMOTE CHILLER...

Page 2: ...R INSTALLATION STEP 2 10 WATER INLET FILTRATION INSTALLATION STEP 3 11 WATER INLET FILTRATION INSTALLATION STEP 4 12 CO2 SUPPLY SYSTEM INSTALLATION 13 COUNTER TOP MODEL INSTALLATION 14 COUNTER TOP MOD...

Page 3: ...LA Minimum Ambient Temperature 40 F 4 5 C Maximum Ambient Temperature 104 F 40 C Inlet Water Pressure 45 PSI to 120 PSI If your inlet water pressure does not meet this minimum pressure requirement you...

Page 4: ...g the unit do not use corrosive acidic products or metal brushes o Do not wash the unit using high pressure water o Connect to a water supply with a pressure of 45 to 120 PSI o The unit must be connec...

Page 5: ...oth sides and 2 inches in back for proper ventilation o For Remote Chiller Model provide ventilated cabinet doors and sides to allow for fresh air into the evaporator coil side and exhaust air out sid...

Page 6: ...ke sure the outer surface of the tube is clear of marks or scratches for a length equal to the O ring thickness to seat properly against the tube 3 Avoid sharp changes in direction when routing the tu...

Page 7: ...FILTRATION SYSTEM REFRIGERATION CARBONATION SYSTEM CO2 SUPPLY SYSTEM NOTE GROUND FAULT CIRCUIT INTERRUPTER GFCI OUTLET RECOMMENDED NOTE CO2 CYLINDER SUPPLIED BY CUSTOMER 10 15 20 LBS CUSTOMER SUPPLIED...

Page 8: ...WALL MOUNT BRACKET BRAIDED HOSE 1 Connect the components in order as shown above Additional assembly adjustment will be required for the Water Leak Protection Device This is detailed in Section 18 NOT...

Page 9: ...as shown above Additional assembly adjustment will be required for the Water Leak Protection Device This is detailed in Section 18 ADAPTER FITTING WATER BLOCK ADAPTER ADAPTER FITTING CUSTOMER SUPPLIE...

Page 10: ...securing the Filter Bracket to the Filter Manifold 3 Secure the Filter Bracket to the wall or other structure using the proper fasteners The Filter Bracket can be turned over for space requirements Th...

Page 11: ...nnect the components in order as shown above 2 Connect 3 8 O D tube from Water Pressure Regulator exit port to the 3 8 elbow inlet port on the Filter Set 1 Cut 3 8 O D tubing to appropriate length 2 C...

Page 12: ...lve 5 Attach the Pressure Regulator to the Cylinder Valve and tighten it firmly Ensure that the supplied Seal O ring is between the CO2 Cylinder Valve and Pressure Regulator fitting 6 Connect the 1 4...

Page 13: ...ting at the rear of the unit 2 Connect the 1 4 O D CO2 tube from the CO2 Cylinder Pressure Regulator to the 1 4 Elbow Fitting at the rear of the unit FROM CO2 CYLINDER FROM FILTER SET STILL WATER TAP...

Page 14: ...ly Push the Tap all the way back into the fitting 4 Screw the Front Panel Fitting to the Tap body To tighten turn the chrome ring on the Front Panel Fitting counter clockwise 5 The Tap should have a t...

Page 15: ...BOW LOCKING CLIP SHANK ADAPTER NUT 1 Assemble the Shank Washer Shank Fitting Shank Adapter Nut Locking Clip and Reducing Elbow as show in the illustration above 2 The Shank Adapter Nut should be hand...

Page 16: ...bing into the tubing insulation provided 2 Connect the 5 16 O D tubing to the left elbow quick connect fitting on the front of the unit 3 Connect the other end of the 5 16 O D tubing to the inlet of t...

Page 17: ...6 Union Fitting on the right side of the Dispense Tower Note This fitting may be a 1 4 x 5 16 reducing fitting or a 5 16 union fitting depending on the Dispense Tower model Remote Chiller Model Connec...

Page 18: ...1liter 15 sec However it may be necessary to adjust this in the field To adjust the flow insert a 6mm Allen wrench into the adjustment screw of the Compensator Valve Turning clockwise the flow rate wi...

Page 19: ...h a valve adjustment 4 To adjust the device separate the two black plastic housings 5 The adjustment location is on the external threaded end of the main housing 6 Insert the key provided into the adj...

Page 20: ...lve located on the carbonator tank by pushing down on the Pressure Relief Ring as shown below Keep it open until water flows from the valve then close it 5 Draw 2 gallons of water from each tap to cle...

Page 21: ...10 Turn the power switch to the ON position The switch will illuminate to indicate that the power is on 11 Adjust the CO2 water flow Left Tap to 1Liter 15 sec flow rate using the Flow Adjustment Lever...

Page 22: ...the front right corner The Drip Tray has a large hole to allow condensation to run freely into the drip tray For this hole to be aligned properly the Drip Tray must be centered left to right and push...

Page 23: ...blespoons of bleach Scrub with a brush or sponge Rinse thoroughly with clean water 9 Clean the O Ring groove and O ring Lubricate the O ring with food grade silicone grease Place the O ring back into...

Page 24: ...ot water on a daily basis Be sure to replace the Drip Tray to its proper location 6 The external stainless steel surface of the cabinet should be cleaned and polished periodically with a non abrasive...

Page 25: ...ILL 6 036289 012 DRIP TRAY 7 036311 201 STILL WATER TAP ASSY 8 036311 202 CO2 COMPENSATED TAP ASSY 9 036387 003 BACKFLOW PREVENTER 10 036535 004 STIRRING PUMP ITEM PART NO DESCRIPTION 11 036544 102 WA...

Page 26: ...HANK ASSY 7 036387 003 BACKFLOW PREVENTER 8 036535 004 STIRRING PUMP 9 036544 102 WATER PUMP 10 038324 004 FRONT PANEL ITEM PART NO DESCRIPTION 11 038327 004 TOP 12 038343 002 ICE BANK CONTROL 13 0383...

Page 27: ...e Reservoir The refrigeration system is not cooling the water the compressor has stopped the fan and agitator are still working The thermal compressor protector has been activated Compressor relay is...

Page 28: ...nt water supply Filters clogged Water pump not working CO2 tank float switch fault Adjust Flow Compensator Valve to proper dispense setting 1 liter 15 sec Replace Filters Check or replace the water pu...

Page 29: ...www naturawater com For technical support contact the Technical Service Department Distributor or Vendor of the unit Or you may contact TECHNICAL ASSISTANCE AND MAINTENANCE 26 CONTACT INFORMATION 036...

Reviews: