11
Installation and Maintenance Manual
12. CO
2
SUPPLY SYSTEM INSTALLATION:
1.
Use only food grade CO
2
(UN1013).
2.
Place the CO
2
Cylinder within 5 feet of the Countertop Water Dispenser or Remote
Chiller.
3.
Use a small chain or strap to secure the CO
2
Cylinder to a secure support.
4.
To ensure no debris in the CO
2
Cylinder Valve, and that the CO
2
Cylinder is
operational, open the valve slowly to allow some CO
2
gas to leak out for a few
seconds. Close the CO
2
Cylinder Valve
5.
Attach the Pressure Regulator to the Cylinder Valve and tighten it
fi
rmly. Ensure that
the supplied Seal/ O-ring is between the CO
2
Cylinder Valve and Pressure Regulator
fi
tting.
6.
Connect the 1/4” O.D. tubing to the CO
2
Pressure Regulator outlet
fi
tting.
7.
Proceed to Section 13 for Counter Top Model Installation, or Sections 15 & 16 for
Remote Chiller Model Installation.
4
3
1
5
CO
2
CYLINDER
CYLINDER VALVE
PRESSURE
REGULATOR
2
SEAL / O’RING
1/4” O.D.
TUBING
NOTE:
THE CO
2
LINE SHOULD
NOT BE PRESSURIZED AT
THIS TIME.
NOTE:
DO NOT CONNECT CO
2
TUBING TO THE UNIT
UNTIL THE INSTALLATION IS COMPLETE.