Chapter 3
Signal Connections
©
National Instruments Corporation
3-9
Power Connections
Pin C1 of both I/O connectors is connected to the +5 V supply from the
VXIbus power supply. These pins are referenced to GND and can supply
power to external circuitry. The +5 V supply has a total of 2 A available.
However, you must limit the current through each connector pin to 1.0 A.
The +5 V power supply has a self-resetting protection circuit breaker in
series. If the circuit breaker protection is activated, simply remove the
circuit causing the heavy current load and the circuit breaker will reset
itself. For more information on these output pins, see the
and
sections in Appendix A,
.
Power rating
1.0 A per pin at +5 V ±10%,
+4.55 to +5.25 VDC at 1 A per pin
Warning
Under no circumstances should you connect these +5 V power pins directly to
ground or to any other voltage source on the VXI-AO-48XDC or any other device.
Doing so can damage the VXI-AO-48XDC and your VXIbus system. National
Instruments is
not
liable for damage resulting from such a connection.